Radiant steel ceiling panels: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
Line 164: Line 164:
# Insert and set labels of other system components (source, pipe-runs, fittings).<br/>{{Info}} [[Introduction_to_the_work_with_the_package_InstalSystem_5#Preparation_of_drawings_for_export.2Fprinting|Preparation of drawings for export/printing]]
# Insert and set labels of other system components (source, pipe-runs, fittings).<br/>{{Info}} [[Introduction_to_the_work_with_the_package_InstalSystem_5#Preparation_of_drawings_for_export.2Fprinting|Preparation of drawings for export/printing]]


===Eksport / wydruk wyników i rysunków===
===Export / print results and drawings===
{{Info}} [[Export / print results and drawings]]
{{Info}} [[Export / print results and drawings]]



Revision as of 13:47, 1 August 2017

Product InstalSystem 5
Type of article SOFTWARE APPLICATION
Source for translation IS 5.0 Beta 33


Range of lesson

This article describes designing heating systems with radiant ceiling panels.

Modules and program configuration

  • InstalSystem 5 package with the following module:
    • Radiant heating&cooling systems with ceiling/wall panels

Inital state

  1. Utworzona została struktura budynku (kondygnacje, hala/pomieszczenia).
    For more information, see: Preparation of building structure.
  2. Wczytany został rysunek z rzutem kondygnacji.
    For more information, see: Import files.
  3. Zostały uzupełnione wartości projektowego obciążenia cieplnego pomieszczeń dla ogrzewania według dostępnych metod:

Steps to perform

Load catalogues and set default data for the project

General data window

SAMPLE PROJECT IN INSTALSYSTEM
Project files

How to calculate downloaded file?

Initial state, isproj
System with radiant ceiling panels in a public building, isproj
Designed with InstalSystem 5 Rev. Beta 33
Required modules InstalSystem basis
Radiant heating system 5
Radiant panel systems 5
{{{module5}}}
Project range Radiant heating
Used catalogues

Basic radiant systems
Neutr. ceiling and wall panels
Brass, cast iron and steel fittings
Copper pipes and fittings acc. to EN 1057
Miscellaneous fittings any manufacturer
Standard insulation catalogue
Neutral valves catalogue - typical design

Type of building commercial building
with basement
2-storey
Building structure Ground floor base drawing, dwg
First floor base drawing, dwg
Drawings range Plan drawings
Prepared by
www.instalsoft.com
Legal disclaimer Copy all or fragments allowed
Calculation results Complete range of calculation results, xls
Complete range of available printouts, pdf
Heating calculation results, pdf
Bill of materials, pdf
Drawing results Ground floor, dwg


  1. Zakładka - Project scope - ustalić zakres projektu: Heating systems / Cooling systems.
  2. Zakładka - Storeys management – zweryfikować i uzupełnić podstawowe parametry:
    • Storey height
    • Default distance between ceiling and distribution pipe-runs to radiant panel system (ΔHpipe-run,pan.)
    • Default distance between ceiling and radiant panels by entering the value in field (Thickness of false ceiling)
  3. Zakładka - Catalogues – wczytać katalogi produktów wymagane do projektu.
  4. Zakładka - Thermal systems / Sources – zweryfikować parametry: Default source use i temperaturę zasilania (θs,H).
  5. Zakładka - Thermal systems / Distribution system / Virtual connections of radiant systems - zaznaczyć opcję Allow system with no manifolds.
  6. Zakładka - Thermal systems / Distribution system / Rury i izolacje - typy i dane domyślne – uzupełnić domyślnie typ rur i izolacji, zweryfikować wartości temperatur w polach Default pipe-run surroundings temperature.
  7. Zakładka - Radiant systems / Panels – uzupełnić domyślne typy i wielkości promienników oraz skorygować wartości minimalnego (Δθ min) i maksymalnego (Δθ max) dopuszczalnego wychłodzenia czynnika. Z podanego przedziału program wyznaczy dla każdego promiennika optymalną wartość w celu uzyskania wymaganej mocy.


    For more information, see: Dane ogólne


Edit installation - radiant ceiling panels

Insert radiant panels and edit graphically

Verify the arrangement of radiant panels, i.e. distances between panels, distances to top slab and external walls, with manufacturer's guidelines.

  1. Select Rad.-ceilings.
  2. Using the AUTO mode settings specify the desired distance between radiant panel and external wall.
    1. Radiant ceiling panel

  3. Insert the radiant panel using the icon Ceiling panel in group Radiant
  4. Adjust the length of the radiant panel to the dimensions of the room by dragging terminal points of the panel and expanding it.
    The length of the panel in the drawing does not have to correspond to the real length of a single panel. Based on the required length, the program will assemble a set of base panels and connection headers connected in series with its total length coresponding to the required length.
  5. Insert subsequent radiant panels by clicking again the Ceiling panel icon or by copying panels already inserted. When necessary modify the settings of the AUTO mode.

Initial calculations - diagnostics of the heat demand coverage in room

  1. Run radiant heating calculations by clicking the icon in the Calculations group.
  2. Verify the heat demand coverage in room in:
    • oknie Diagnostics przeglądając listę ostrzeżeń
      2. Weryfikacja pokrycia potrzeb cieplnych pomieszczenia w oknie Diagnostics

    • oknie Results na zakładkach - List of rooms - heating
    • chmurce podpowiedzi wyświetlanej po ustawieniu kursora myszy w obszarze panelu

Modify data to adjust the attained output to the required output

  1. Adjust the following data and parameters:
    • supply temperature in the general data of the source (θs,H).
      3. Korekta temperatury zasilania w General data

    • required drop of temperature of the medium in the radiant panel (Δθreq,H).
      4. Correction of temperature drop of medium in radiant panel (Δθwym,H)

    • number/size of radiant panels
  2. Recalculate the project – verify the effect of the changes made on the attained heating output.

Edit installation - append drawings with the medium distribution system

  1. Upon attaining satisfactory results for the coverage of heat demand in rooms, insert the other components of the system (source, pipe-runs, fittings) and connect them to the radiant panels.

Make complete calculations including system balancing and bill of materials

  1. Make calculations for radiant heating by clicking the icon in the Calculations group.
  2. Verify the diagnostics and calculation results, in particular:
    • Required source parameters - the Results window – Results Heating/General results heating tab
    • Flow balance – the Results window – Circuits tab
    • Bill of materials - the Results window – Bill of materials - heating / cooling tab
      For more information, see: Calculations and diagnostics

Verify visually arrangement of the system in 3D view

  1. Open the 3D view window and check system arrangement. If necessary, modify the elevations of the components and positions of connection points. Recalculate the project if corrections were made.
    For more information, see: Verification of the correctness of installation structure
    5. 3D view

Prepare drawings for printing/export

  1. Verify the drawing style of the panel in 2D and 3D views and the level of detail of information provided in the label. Configuration is given in the General data window.


6. Konfiguracja zawartości etykiety panelu.


  1. Insert and set labels of other system components (source, pipe-runs, fittings).
    For more information, see: Preparation of drawings for export/printing

Export / print results and drawings

For more information, see: Export / print results and drawings