Release notes InstalSystem 5: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
Line 21: Line 21:
====Modules:====
====Modules:====
'''Base module, including InstalSystem Manager'''
'''Base module, including InstalSystem Manager'''
* Poprawiono wysyłanie formularza zgłoszenia problemu po niekontrolowanym zamknięciu aplikacji.
* Fixed the problem with sending the Problem report form after an uncontrolled closing the application.
* Zakres wyświetlanych katalogów w danych ogólnych został dostosowany do dostępnych modułów obliczeniowych dla pakietu.
* The scope of the displayed catalogs in the general data has been adapted to the available project scope for the package.
* Dodano ikonki dla plików .isproj wyświetlanych w Zarządcy pakietu oraz w oknie Eksploratora Windows.
* Added icons for the files .isproj displayed in the Manager and in the Windows Explorer window.


'''Radiant heating - loop systems'''
'''Radiant heating - loop systems'''
* Zmieniono oznaczenia węzłów siatki rysunkowej wspomagającej ręczne rysowanie pętli.
* Changed the designation of nodes in the grid supporting the manual drawing of the loop.
* Dodano komunikat informujący o braku możliwości usunięcia pętli grzewczo-chłodzących.
* Added message indicating the inability to remove the RHC loop.


'''Heating network with balancing'''
'''Heating network with balancing'''
* Poprawiono automatyczny dobór szafek rozdzielaczowych.
* Fixed the automatic selection of manifolds cabinets.
* Poprawiono propagację danych domykanych dla szafki rozdzielaczowej.
* Improved the propagation of data closed for manifold cabinet.


====Articles in HelpSystem:====
====Articles in HelpSystem:====

Revision as of 13:37, 25 November 2015

Product InstalSystem 5
Type of article PRODUCT INFORMATION
Source for translation IS 5.0 Beta 22


Information about changes

Version BETA 23 Rev. 15.11.2

Modules:

Base module, including InstalSystem Manager

  • Fixed the problem with sending the Problem report form after an uncontrolled closing the application.
  • The scope of the displayed catalogs in the general data has been adapted to the available project scope for the package.
  • Added icons for the files .isproj displayed in the Manager and in the Windows Explorer window.

Radiant heating - loop systems

  • Changed the designation of nodes in the grid supporting the manual drawing of the loop.
  • Added message indicating the inability to remove the RHC loop.

Heating network with balancing

  • Fixed the automatic selection of manifolds cabinets.
  • Improved the propagation of data closed for manifold cabinet.

Articles in HelpSystem:

Version BETA 22 Rev. 15.10.2

Modules:

Base module, including InstalSystem Manager

  • Added graphical rulers (horizontal and vertical) to help verify the scale of loaded underlay.
  • Improved ORTO and AUTO modes.
  • Fixed the problem with sending error report form after crash of the program.
  • Improved overall stability and quality of the program by eliminating the reported errors.

Articles in HelpSystem:

Version BETA 21 Rev. 15.9.2

Modules:

Base module, including InstalSystem Manager

  • Modified the way of importing base drawing files.
  • Added a Select components in rectangle function under the left mouse button.
  • Improved acting of ORTO mode when moving objects.
  • Accelerated loading of the newly created or saved again files, as a consequence the files created on previous versions may load slower.

Radiant heating - loop systems

  • Added the possibility of parallel connection of several RHC loop to one common outlet from the manifold.
  • Introduced balance diagnostics of the RHC loop connected to the manifold with not integrated balancing valves, and the possibility of adding on the pipe-runs valves which are balancing these objects.

Heating network with balancing

  • Added the possibility to use multi-circuit heating floor zone.
  • Introduced balance diagnostics of the circuits by the heating floor zones in the systems without the manifold.
  • Added the possibility to supply multi-circuit heating floor zone from several manifolds.
  • Introduced the possibility of supplying heating/cooling zones directly from the virtual or graphical source, without the usage of a manifold.

Articles in HelpSystem:

Version BETA 16.1 Rev. 15.5.17

Modules:

Base module, including InstalSystem Manager

  • Added new tool to search and select items in the project.
  • Improved the import and export of bases.
  • Introduced the control of print range which based on the edition range and the elements' styles.
  • Introduced the possibility to highlight and select project's elements to which messages on the diagnostic list referred to.
  • Added the possibility to highlight on the worksheet elements forming the circuit of specified receptor from this worksheet.

Radiant heating - loop systems

  • Improved the functionality of pipe feed automatic generation.

Articles in HelpSystem:

Version BETA 15.1 Rev. 15.4.21

Initial scope of modules:

  • Base module, including InstalSystem Manager
  • Radiant heating - loop systems
  • Cooling mode for radiant systems
  • Heating network with balancing
  • BIM Interface (gbXML)

Initial state of articles in HelpSystem