| Line 52: | Line 52: | ||
====<IS_TS id=stringTypElementu/>==== | ====<IS_TS id=stringTypElementu/>==== | ||
The ''<IS_TS id=stringTypElementu/>'' of the ''<IS_TS id=iNameCOReduktorTemp/>'' can be chosen from the: | The ''<IS_TS id=stringTypElementu/>'' of the ''<IS_TS id=iNameCOReduktorTemp/>'' can be chosen from the: | ||
* Neutral catalogue ''Standard mixers, pump and bypass units'' | * Neutral catalogue ''Standard mixers, pump and bypass units''. Depending on the use of the ''<IS_TS id=iNameCOReduktorTemp/>'', there are three variants be selected: | ||
** ''Mixing supply and return units'' - contain ''<IS_TS id=pinNamePompa/>'' and bypass | ** ''Mixing supply and return units'' - contain a ''<IS_TS id=pinNamePompa/>'' and bypass, used to simulate mixing, under design conditions, of the return medium with the supply medium, which leads to a decrease in the supply temperature in ''<IS_TS id=InstalacjeGrzewcze/>'' or an increase in the supply temperature in ''<IS_TS id=InstalacjeChlodnicze/>''; | ||
** ''Pump units'', | ** ''Pump units'' - acts like ''<IS_TS id=pinNamePompa/>'', ensuring the circulation of the medium. However, as a block of elements containing a ''<IS_TS id=pinNamePompa/>'', it can be found in some manufacturers catalogues. Usually one or two types of real pumps are available in such blocks. This is the case where the program uses real ''<IS_TS id=''<IS_TS id=pinNamePompa/>''/>'', presented ''<IS_TS id=DataEditorTable/>'' window; | ||
** ''Units with supply to return bypass''.<br/>[[File:Pump and Mixer type.png|900 px|left|thumb|5. <IS_TS id=iNameCOReduktorTemp/> <IS_TS id=stringTypElementu/>.]]<br clear="all"/> | ** ''Units with supply to return bypass'' - contain only a bypass, used to simulate the possibility of mixing of the return medium with the supply medium, but not under designing conditions - the input and output flow rates remain equal.<br/>[[File:Pump and Mixer type.png|900 px|left|thumb|5. <IS_TS id=iNameCOReduktorTemp/> <IS_TS id=stringTypElementu/>.]]<br clear="all"/> | ||
* Catalogues, provided by the particular manufacturer, selected in the ''<IS_TS id=rsDanogi/>'' window / ''<IS_TS id=strDlgKatalogiObslugaKatalogowHint/>'' tab. {{Info}} [[Using catalogues and catalogues data in the project]].<br/><br/> | * Catalogues, provided by the particular manufacturer, selected in the ''<IS_TS id=rsDanogi/>'' window / ''<IS_TS id=strDlgKatalogiObslugaKatalogowHint/>'' tab. {{Info}} [[Using catalogues and catalogues data in the project]].<br/><br/> | ||
Revision as of 12:24, 5 January 2026
| Product | InstalSystem 5 |
| Type of article | FUNCTION AND TOOL |
| Source for translation | 2025-12-17 |
Description
The article describes the ways of using such elements as Pump and Mixer / Pump unit in Designing heating systems with convective radiators and Designing of radiant heating floor and wall installation.
Location in program
Elements Pump and Mixer / Pump unit are available in the Distribution - thermal installations tab in the Main tools menu, when Convectional, Rad.-floors,walls or Rad.-ceilings editing scope is active.

Examples of use
Pump
The Pump is inserted as a separate element on the pipe-run section.
The following data can be adjust, if necessary, in the Data table window:
- H - Pump head;
- Rotation angle.
If the Pump head is left to be sized by the program, the result can be read from the hint after performing Calculations of Heating systems:
Note: The appearance of the Label can be modified according to personal preferences. For more information, see: Label editing.
(Optionally) Use manufacturer catalogues or sizing software to select the particular Pump model and adjust its characteristics.
Mixer / Pump unit
The Mixer / Pump unit is a block with a fixed set of elements. The functionality, defined depending on the project purposes (should it be a pump unit or a mixer, typically with a pump inside), is achieved by selecting the appropriate Type from the Catalogues provided in the program. The unit can be neutral or from the particular manufacture.
Note: To insert the Mixer / Pump unit element, use one of the following ways:
- Place the Mixer / Pump unit element on an already drawn pipe-run using the function Insert dividing point and deleting unnecessary pipe-runs.
- Draw sequentially the pipe-runs and the Mixer / Pump unit element.
Orientation
The Orientation of the Mixer / Pump unit is selected in the Data table window from the available variants.

Use
The Use of the Mixer / Pump unit is determined in accordance with the Project scope indicated in the General data window:
- Heating,
- Heating and cooling efficiency.
Type
The Type of the Mixer / Pump unit can be chosen from the:
- Neutral catalogue Standard mixers, pump and bypass units. Depending on the use of the Mixer / Pump unit , there are three variants be selected:
- Mixing supply and return units - contain a Pump and bypass, used to simulate mixing, under design conditions, of the return medium with the supply medium, which leads to a decrease in the supply temperature in Heating systems or an increase in the supply temperature in Cooling systems;
- Pump units - acts like Pump, ensuring the circulation of the medium. However, as a block of elements containing a Pump, it can be found in some manufacturers catalogues. Usually one or two types of real pumps are available in such blocks. This is the case where the program uses real Pump/>, presented Data table window;
- Units with supply to return bypass - contain only a bypass, used to simulate the possibility of mixing of the return medium with the supply medium, but not under designing conditions - the input and output flow rates remain equal.

5. Mixer / Pump unit Type.
- Catalogues, provided by the particular manufacturer, selected in the General data window / Catalogues tab. For more information, see: Using catalogues and catalogues data in the project.
2D/3D view style
Presentation 2D and Presentation 3D of the Mixer / Pump unit can be:
- Detailed,
- Simplified.
The dimensions of the Mixer / Pump unit can be modified, if necessary.

Outlet temperature (mixing unit)
Outlet temperature (Heating) and Outlet temperature (Cooling) in the Mixing unit are determined automatically in accordance with the data set in the General data window for the Sources. If necessary, the values can be adjusted.

Results
The Mixer / Pump unit characteristics are presented after performing Calculations of Heating systems:
- In the table, displayed in the working space,
- On the element Label,
- In the Results tables,

8. Results. - In the Mixer / control unit chart for the Mixing unit. For more information, see: Mixer / control unit chart.