Pump and Mixing unit: Difference between revisions
Klintsevicho (talk | contribs) No edit summary |
Klintsevicho (talk | contribs) No edit summary |
||
| Line 36: | Line 36: | ||
===<IS_TS id=iNameCOReduktorTemp/>=== | ===<IS_TS id=iNameCOReduktorTemp/>=== | ||
The ''<IS_TS id=iNameCOReduktorTemp/>'' is | The ''<IS_TS id=iNameCOReduktorTemp/>'' is a block with a fixed set of elements. The functionality, defined depending on the project purposes (should it be a pump unit or a mixer, typically with a pump inside), is achiever by the selection of a proper type, selected from the ''<IS_TS id=strDlgKatalogiObslugaKatalogowHint/>'' provided in the program. The unit can be neutral or from the particular manufacture.<br/> | ||
'''''Note:''''' To insert the ''<IS_TS id=iNameCOReduktorTemp/>'' element, use one of the following ways: | '''''Note:''''' To insert the ''<IS_TS id=iNameCOReduktorTemp/>'' element, use one of the following ways: | ||
* Place the ''<IS_TS id=iNameCOReduktorTemp/>'' element on an already drawn pipe-run using the function ''<IS_TS id=InsertEndPoint/>'' and deleting unnecessary pipe-runs. <br/>{{#ev:youtube|8Hm3ZQ0LksU|900||||rel=0}}<br clear="all"/> | * Place the ''<IS_TS id=iNameCOReduktorTemp/>'' element on an already drawn pipe-run using the function ''<IS_TS id=InsertEndPoint/>'' and deleting unnecessary pipe-runs. <br/>{{#ev:youtube|8Hm3ZQ0LksU|900||||rel=0}}<br clear="all"/> | ||
| Line 52: | Line 53: | ||
The ''<IS_TS id=stringTypElementu/>'' of the ''<IS_TS id=iNameCOReduktorTemp/>'' can be chosen from the: | The ''<IS_TS id=stringTypElementu/>'' of the ''<IS_TS id=iNameCOReduktorTemp/>'' can be chosen from the: | ||
* Neutral catalogue ''Standard mixers, pump and bypass units'', provided by the program. Depending on the use of the ''<IS_TS id=iNameCOReduktorTemp/>'', there are three variants be selected: | * Neutral catalogue ''Standard mixers, pump and bypass units'', provided by the program. Depending on the use of the ''<IS_TS id=iNameCOReduktorTemp/>'', there are three variants be selected: | ||
** ''Mixing supply and return units'', | ** ''Mixing supply and return units'' - contain ''<IS_TS id=pinNamePompa/>'' and bypass are used to simulate mixing, in designing conditions, of returning medium to the supply line, which results in reducing the supply temperature (in heating), or raising it (in cooling), | ||
** ''Pump units'', | ** ''Pump units'', | ||
** ''Units with supply to return bypass''.<br/>[[File:Pump and Mixer type.png|900 px|left|thumb|5. <IS_TS id=iNameCOReduktorTemp/> <IS_TS id=stringTypElementu/>.]]<br clear="all"/> | ** ''Units with supply to return bypass''.<br/>[[File:Pump and Mixer type.png|900 px|left|thumb|5. <IS_TS id=iNameCOReduktorTemp/> <IS_TS id=stringTypElementu/>.]]<br clear="all"/> | ||
Revision as of 11:17, 5 January 2026
| Product | InstalSystem 5 |
| Type of article | FUNCTION AND TOOL |
| Source for translation | 2025-12-17 |
Description
The article describes the ways of using such elements as Pump and Mixer / Pump unit in Designing heating systems with convective radiators and Designing of radiant heating floor and wall installation.
Location in program
Elements Pump and Mixer / Pump unit are available in the Distribution - thermal installations tab in the Main tools menu, when Convectional, Rad.-floors,walls or Rad.-ceilings editing scope is active.

Examples of use
Pump
The Pump is inserted as a separate element on the pipe-run section.
The following data can be adjust, if necessary, in the Data table window:
- H - Pump head;
- Rotation angle.
If the Pump head is left to be sized by the program, the result can be read from the hint after performing Calculations of Heating systems:
Note: The appearance of the Label can be modified according to personal preferences. For more information, see: Label editing.
(Optionally) Use manufacturer catalogues or sizing software to select the particular Pump model and adjust its characteristics.
Mixer / Pump unit
The Mixer / Pump unit is a block with a fixed set of elements. The functionality, defined depending on the project purposes (should it be a pump unit or a mixer, typically with a pump inside), is achiever by the selection of a proper type, selected from the Catalogues provided in the program. The unit can be neutral or from the particular manufacture.
Note: To insert the Mixer / Pump unit element, use one of the following ways:
- Place the Mixer / Pump unit element on an already drawn pipe-run using the function Insert dividing point and deleting unnecessary pipe-runs.
- Draw sequentially the pipe-runs and the Mixer / Pump unit element.
Orientation
The Orientation of the Mixer / Pump unit is selected in the Data table window from the available variants.

Use
The Use of the Mixer / Pump unit is determined in accordance with the Project scope indicated in the General data window:
- Heating,
- Heating and cooling efficiency.
Type
The Type of the Mixer / Pump unit can be chosen from the:
- Neutral catalogue Standard mixers, pump and bypass units, provided by the program. Depending on the use of the Mixer / Pump unit , there are three variants be selected:
- Mixing supply and return units - contain Pump and bypass are used to simulate mixing, in designing conditions, of returning medium to the supply line, which results in reducing the supply temperature (in heating), or raising it (in cooling),
- Pump units,
- Units with supply to return bypass.

5. Mixer / Pump unit Type.
- Catalogues, provided by the particular manufacturer, selected in the General data window / Catalogues tab. For more information, see: Using catalogues and catalogues data in the project.
2D/3D view style
Presentation 2D and Presentation 3D of the Mixer / Pump unit can be:
- Detailed,
- Simplified.
The dimensions of the Mixer / Pump unit can be modified, if necessary.

Outlet temperature (mixing unit)
Outlet temperature (Heating) and Outlet temperature (Cooling) in the Mixing unit are determined automatically in accordance with the data set in the General data window for the Sources. If necessary, the values can be adjusted.

Results
The Mixer / Pump unit characteristics are presented after performing Calculations of Heating systems:
- In the table, displayed in the working space,
- On the element Label,
- In the Results tables,

8. Results. - In the Mixer / control unit chart for the Mixing unit. For more information, see: Mixer / control unit chart.