Project description

Project illustrates an example how to design radiant cooling installation and convective installation in a mixed building type. Source, which is common for all elements, gives temperature 9°C. It directly feeds terminal unit with imposed pressure drop simulating passive chilled beams. It supplies cooling walls in the hall by mixer with temperature 18°C.
At the same time, medium is delivered to a manifold with mixing set, which feeds with temperature 18°C:

  • ceiling panels in serial-parallel system (Tichelmann system with common connection to manifold),
  • wall pannel parallel connected in Tichelmann system,
  • cooling ceiling parallel connected in Tichelmann system,
  • cooling ceiling with classic feeds generates automatically.

Files to download and project information

Project files

How to calculate downloaded file?

[{{{initial_state1}}} {{{initial_state_name1}}}]
[{{{initial_state2}}} {{{initial_state_name2}}}]
[{{{final_state1}}} {{{final_state_name1}}}]
[{{{final_state2}}} {{{final_state_name2}}}]
Designed with [[{{{commercial_product}}}]] Rev. {{{rev}}}
Required modules {{{module1}}}
{{{module2}}}
{{{module3}}}
{{{module4}}}
{{{module5}}}
Project range {{{range}}}
Used catalogues

{{{catalogue1}}}
{{{catalogue2}}}
{{{catalogue3}}}
{{{catalogue4}}}
{{{catalogue5}}}
{{{catalogue6}}}
{{{catalogue7}}}
{{{catalogue8}}}
{{{catalogue9}}}
{{{catalogue10}}}

Type of building {{{type}}}
{{{basement}}}
{{{number_of_storeys}}}
Building structure [{{{building_structure1}}} {{{file_name1}}}]
[{{{building_structure2}}} {{{file_name2}}}]
[{{{building_structure3}}} {{{file_name3}}}]
[{{{building_structure4}}} {{{file_name4}}}]
Drawings range {{{drawings_range}}}
Prepared by [[{{{logo}}}|100px]]
[{{{www}}}]
Legal disclaimer {{{legal_disclaimer}}}
Calculation results [{{{calculation_results1}}} {{{results_title1}}}]
[{{{calculation_results2}}} {{{results_title2}}}]
[{{{calculation_results3}}} {{{results_title3}}}]
[{{{calculation_results4}}} {{{results_title4}}}]
[{{{calculation_results5}}} {{{results_title5}}}]
Drawing results [{{{drawing_result1}}} {{{drawing_title1}}}]
[{{{drawing_result2}}} {{{drawing_title2}}}]
[{{{drawing_result3}}} {{{drawing_title3}}}]
[{{{drawing_result4}}} {{{drawing_title4}}}]
[{{{drawing_result5}}} {{{drawing_title5}}}]
[{{{drawing_result6}}} {{{drawing_title6}}}]


|initial_file_name2 =

|final_state1 = https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Installation-with-cooling-systems-in-multifunctional-building.isproj |final_state_name1 = Installation with cooling systems in multifunctional building, isproj |fs2 = |final_state_name2 =

|commercial_product = InstalSystem 5 |rev = GOLD Rev. 14.0

|module1 =Base module |module2 =Radiant systems |module3 =Panel systems |module4 =Heating systems |module5 =Cooling systems

|range = Radiant cooling and panel cooling systems

|catalogue1=Basic radiant systems |catalogue2=Neutral ceiling and wall panels |catalogue3=Brass and steel pipe couplings and fittings |catalogue4=Copper pipes and fittings EN 1057 |catalogue5=Miscellaneous fittings of any make |catalogue6=PEX (pipe and fittings) acc. to EN ISO 15875 |catalogue7=Standard mixers, pump and bypass units |catalogue8=Standard insulation catalogue |catalogue9=Media |catalogue10=Neutral valves catalogue-typical construction |c11 = |c12 = |c13 = |c14 =

|type = multifunctional building |basement = with basement |number_of_storeys = 4-storey

|building_structure1 =https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Multifunctional-building-basement.dwg |file_name1 = Base drawing basement, dwg |building_structure2 =https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Multifunctional-building-ground-floor.dwg |file_name2 = Base drawing ground floor, dwg |building_structure3 =https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Multifunctional-building-first-floor.dwg |file_name3 = Base drawing first floor, dwg |building_structure4 =https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Multifunctional-building-attic.dwg |file_name4 = Base drawing attic, dwg |bs5 = |file_name5 =

|drawings_range = Plan view

|logo =File:Logo-instalsoft-new.png |www =https://instalsoft.com www.instalsoft.com

|legal_disclaimer =The whole file or parts of the project may be copied

|calculation_results1 =https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Full-printout.xlsx |results_title1 =Full printout, xls |calculation_results2 =https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Full-printout.pdf |results_title2 =Full printout, pdf |calculation_results3 =http://download.instalsoft.com/public/helpsystem/PP/Installation-with-cooling-systems-in-multifunctional-building/General-cooling-results.pdf |results_title3 =General cooling results, pdf |calculation_results4 =https://download.instalsoft.com/public/helpsystem/PP/Installation-with-cooling-systems-in-multifunctional-building/Bill-components.pdf |results_title4 =Bill components, pdf |calculation_results5 =https://download.instalsoft.com/public/helpsystem/PP/Installation-with-cooling-systems-in-multifunctional-building/Installation-parameters.pdf |results_title5 =Installation parameter, pdf

|drawing_result1=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Basement-export.dwg |drawing_title1 = Basement, dwg |drawing_result2=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Ground-floor-export.dwg |drawing_title2 = Ground floor, dwg |drawing_result3=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/First-floor-export.dwg |drawing_title3 = First floor, dwg |drawing_result4=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Attic-floor-export.dwg |drawing_title4 = Attic floor, dwg |drawing_result5=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Basement-print.pdf |drawing_title5 = Basement, pdf |drawing_result6=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Ground-floor-print.pdf |drawing_title6 = Ground floor, pdf |drawing_result7=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/First-floor-print.pdf |drawing_title7 = First floor, pdf |drawing_result8=https://download.instalsoft.com/public/helpsystem/EN/PP/Installation-with-cooling-systems-in-multifunctional-building/Attic-print.pdf |drawing_title8 = Attic floor, pdf }}

1. Cooling installation - passive chilled beams
2. Cooling installation - ceiling and walls panels, cooling ceiling

-->