Linear and point thermal bridges
Revision as of 13:00, 23 April 2025 by Klintsevicho (talk | contribs) (→Scenario I - method of accounting linear thermal bridges)
| Product | InstalSystem 5 |
| Type of article | FUNCTION AND TOOL |
| Source for translation | 2025-04-22 |
DESCRIPTION
This article describes methods of accounting linear and point thermal bridges in thermal calculations of partitions and building structures.
LOCATION IN THE PROGRAM
The selection of the Thermal bridges calculation method is available in the General data window, Calculation standards and options tab.

EXAMPLE OF USE
Scenario I - Simplified method of accounting linear thermal bridges
- Editing the default data:
- In the General data window choose Simplified for the Thermal bridges calculation method. Note: this method is available for the EN standards;
- (Optionally) Set auto mode for the Manner of making allowance for thermal bridges. This causes the "auto mode" status to be set for all fields of the ΔUtb column available on the form Building structure / Building (rooms view).
It initiates the following default values:
- for the external partitions (EW, EWi, ED, EF, RO ) or in contact with the ground ( WG, FL ):
(delta)U = 0.05 W/m2K /as for “building thermal bridges accounting”/ in the case of internal partitions ( SW, StW, DW, OW ): (delta)U = 0.00 W/m2K