Automatically generate schematic views
| Product | InstalSystem 5 |
| Type of article | FUNCTIONS AND TOOLS |
| Source for translation | REVISION Rev. 17.1 |
Description
This article describes the method of creating automatic schematic views of installations based on an installation model of Application: Heating systems or Application: Cooling systems type with an option to manually edit these views, insert fittings and regenerate the view at any time.
Schematic views of installations are generated in the 2D editor using Starting point (thermal installations) components.
This functionality is currently under development and was included in the BETA version.
Location in the program
Icons of components and of functions for controlling the automatical generation of schematic views are available in the 2D editor window on the Main tools bar in the Schematic view section within the Convectional, Rad.-floors,walls, Rad.-ceilings editing scopes.

The generated Sheet type: Schematic view components are at the bottom of the sheet list.

Examples of use
Check connections
Checking the correctness of connections using the Check connections operation or by pressing Shift+F2 is necessary for the proper generation of the schematic view. The project file can include messages on error relevance, but these messages cannot relate to connection errors.
Presentation of the basic components and functions for controlling automatic generation of schematic views
Starting point (thermal installations)
This is the starting point in the installation from which the schematic view is generated. It has to be assigned a unique symbol. Many Starting point (thermal installations) components can be inserted, and each of them generates a separate Sheet type: Schematic view ![]()
The Starting point (thermal installations) can be placed on:
- Leading pipe-run
Indication of the pipe-run which has a priority when generating a schematic view. This is important when generating an asymmetrical installation (supply and return pipe-runs arranged along different routes). All junctions (tees, crosspieces) are also marked on leading pipe-runs.
3. Junction(tee)
The scope can be reduced:- Installation between source and risers - generates the schematic view from the indicated point to risers, excluding the risers
- Risers - generates the schematic view from the indicated point to risers, including the risers
- Installation behind risers - generates the schematic view from the indicated point beyond the risers to terminal units. If an installation includes stations, the schematic view is terminated at the station, if the installation includes manifolds, the schematic view is terminated at the manifold.
- Installation behind flat stations - generates the schematic view from the indicated point to the station including the installation beyond the station (checkbox Installation behind risers must be checked)
- Installation behind manifold - generates the schematic view beyond the manifolds (checkbox Installation behind risers must be checked)
- Control over automatic labelling.

10. Schematic view - labels control - Apparent shift
Enables display in the schematic view of pipe-runs that are on the same level (elevation). Does not affect the elevation of the pipe-run in the model. - Show room extent
Marked rooms and their labels.
6. Show room extent 
7. Show room extent - room marked in the schematic view - Generate schematic views
Unchecking this option disables the generation of the schematic view during subsequent generations, e.g. new settings for the automatic schematic view control functions will not be taken into account. However, disabling this option does not affect installation components. The installation components are refreshed automatically, i.e. the number of installation components in the model always corresponds to the number of installation components in the schematic view. If this option is disabled, a padlock icon is shown in the sheet selection list
.
8. 'Generate schematic views
Control point
Pozwala na kontrolę kierunku generacji poszczególnych gałęzi na rozwinięciu oraz na modyfikację przebiegu trasy wiodącej. Musi być wstawiony na działkę wiodącą. Punkt sterujący zmienia przebieg rozwinięcia począwszy od węzła, za którym został wstawiony. Elementów Control point może być wstawionych wiele i mogą być wstawione na Sheet type: Schematic view lub Sheet type: Plan view.

- Direction.
Pozwala określić np. czy fragment instalacji (np.: Riser) ma być traktowany jako ułożony po prawej lub lewej stronie od elementu Source. Analogicznie można określić czy fragment instalacji jest po prawej lub lewej stronie od elementu Riser. Na filmie zaprezentowano przeniesienie na rozwinięciu dwóch pionów na lewo od źródła.
- Disconnect on schematic view.
Pozwala na korektę przebiegu trasy wiodącej rozwinięcia. Na filmie zaprezentowano zmianę trasy wiodącej w taki sposób, aby trasa krytyczna instalacji była zaprezentowana jako pierwsza.
Endpoint
Program nie generuje rozwinięcia instalacji znajdującej się za elementem Endpoint. Ta część instalacji zastępowana jest elementem Fragment of installation. Element Endpoint musi mieć nadany unikalny symbol.
Na filmie zaprezentowano eliminację pionu z rozwinięcia.
Fragmenty instalacji nie podlegające automatycznemu generowaniu rozwinięcia
- Instalacje z panelami sufitowymi.
- Instalacje z panelami ściennymi.
Takie fragmenty są automatycznie kończone elementem Fragment of installation.
Edycja ręczna i konfiguracja
- Wstawianie elementów niezależnych.
Na Sheet type: Schematic view można wstawiać:- dodatkowe etykiety (np.: etykiety działek). Można zmieniać również położenie wstawionych etykiet i program zachowuje ich położenie po regeneracji rozwinięcia,
- zawory,
- armaturę wstawianą na działki,
- armaturę grzejnikową.
Dodatkowe informacje
- Plik projektu z programu InstalSystem 4 zawierający Sheet type: Schematic view wczytany do InstalSystem 5.
Taki arkusz nie jest konwertowany na Sheet type: Schematic view z programu InstalSystem 5 i jest on usuwany podczas wczytywania, o czym program informuje odpowiednim komunikatem diagnostyki.