How to eliminate: "Max. working load %.1f exceeds permissible value %.1f for selected floor construction (insulation). Insulation was not determined"

From HelpSystem
Jump to navigation Jump to search


Product InstalSystem 5
Type of article TIP&TRICK
Source for translation 2022-03-30


Problem description

Problems related to the design of the heating/cooling floor construction are indicated with the following message:

  • Max. working load %.1f exceeds permissible value %.1f for selected floor construction (insulation). Insulation was not determined.

Instead of the %.1f parameter, the load value in kN/m2 is displayed. The maximum value depends on the selected system, while the working load arises from the design data.

The diagnostic message is displayed when:

  • the default Max. working load specified in General data on the Floor systems tab exceeds the permissible load value listed in the catalogue for the given floor system;
  • Max. working load declared in Floor build-up ... for the selected Heating/Cooling Floor Zone exceeds the permissible load value listed in the catalogue for the given floor system.

Solution

  • Default maximum permissible operational load for underfloor systems jest propagowane do wszystkich elementów Heating/Cooling Floor Zone. W sytuacji wystąpienia komunikatu zmiany wartości dla Max. working load można dokonać w oknie General data w sekcji Floor systems.
    1. Ustawienia w polu Max. working load w oknie General data w zakładce Floor systems.

  • Zmiany (zmniejszenia wartości) można również dokonać tylko dla wybranych elementów Heating/Cooling Floor Zone w polu Max. working load w edytorze Floor build-up ... wywoływanym z okna Data table.
    2. Ustawienia wartości w polu Max. working load.