==Inital state==
==Inital state==
The file in an initial state takes into account the graphical presentation of the ground and the floor, shown in two separate sheets.<br/><span style="color: cornflowerblue">More about ''editing the structure'': [[Graphical presentation of the building structure]]<!--Case 98632--></span>.''<br/>
The file in an initial state takes into account the graphical presentation of the ground and the floor, shown in two separate sheets.<br/><span style="color: cornflowerblue">More about ''editing the structure'': [[Graphical presentation of the building structure]]<!--Case 98632--></span>.''<br/>
The file also contains a piece of the water supply including inserted receivers and water supply risers. Tips on how to make such a basic file are contained in the article [[Design of water installation - basics]].
The file also contains a piece of the water supply including inserted receivers and water supply stacks. Tips on how to make such a basic file are contained in the article [[Design of water installation - basics]].
:*The file in an initial state:[[File:Instal-san-t-example-file-of-ring-installation-initial-state.ISB]]<br/><span style="color: cornflowerblue">More about ''hot to download the file'': [[Downloading and calculating file from HelpSystem]].</span>
:*The file in an initial state:[[File:Instal-san-t-example-file-of-ring-installation-initial-state.ISB]]<br/><span style="color: cornflowerblue">More about ''hot to download the file'': [[Downloading and calculating file from HelpSystem]].</span>
<!--===Projekt===
<!--===Projekt===
Line 36: Line 36:
==='''Running application and configuration of basic project data'''===
==='''Running application and configuration of basic project data'''===
# Run the program '''Instal-san T'''.
# Run the program '''Instal-san T'''.
# Load the file with the prepared structure of the building and fragment of installation including receivers and water supply risers.
# Load the file with the prepared structure of the building and fragment of installation including receivers and water supply stacks.




Line 45: Line 45:
==='''Connecting the receivers'''===
==='''Connecting the receivers'''===
# Connections to the receivers by U-fittings system with direct inclusion tap to the T-fitting:
# Connections to the receivers by U-fittings system with direct inclusion tap to the T-fitting:
#* Highlight a piece of installation, to take into account the receivers and the  pipe-runs you want to connect to, and then select the key combination Shift + Ctrl + A or an option "Automatically connect terminal units" available in menu for Components.<br />[[File:Ring-installation.png|700 px|left|thumb|2. Receivers connect by T-fittings]]<br/>[[File:Pipe-type-vitual.png|350 px|center|thumb|3. Virtual pipe-runs in connections with T-fittings]]<br clear="all"/>
#* Highlight a piece of installation, to take into account the receivers and the  pipe-runs want to connect to, and then select the key combination Shift + Ctrl + A or an option "Automatically connect terminal units" available in menu for Components.<br />[[File:Ring-installation.png|700 px|left|thumb|2. Receivers connect by T-fittings]]<br/>[[File:Pipe-type-vitual.png|350 px|center|thumb|3. Virtual pipe-runs in connections with T-fittings]]<br clear="all"/>
#* In U-fittings system, after selecting "Automatically connect terminal units", give the type of pipe-run "virtual" for the pipe-runs comprising approaches to the receivers.
#* In U-fittings system, after selecting "Automatically connect terminal units", give the type of pipe-run "virtual" for the pipe-runs comprising approaches to the receivers.
#* Close the ring.
#* Close the ring.
# Connecting the receivers in the system of direct inclusion of tap for the U-fitting:
# Connecting the receivers in the system of direct inclusion of tap for the U-fitting:
#* Select the portion of the installation, to take into account the receivers and the plot you want to connect to, and then select the key combination Shift + Ctrl + L or an option "Automatically connect the receivers in the system trójnikowym" shared elements on the menu..<br />[[File:Tee-connections-ring-installation.png|700 px|left|thumb|4. Odbiorniki podłączone za pomocą U-kształtek]]<br/>[[File:Pipe-type-virtual-tee.png|350 px|center|thumb|5. Działki wirtualne przy podłączeniach z U-kształtkami]]<br clear="all"/>
#* Select the part of the installation, to take into account the receivers and the pipe-runs want to connect to, and then select the key combination Shift + Ctrl + L or an option "Receptor connect automatically with U-Fitting for looping" available in menu for Components.<br />[[File:Tee-connections-ring-installation.png|700 px|left|thumb|4. Receivers connected using U-fittings]]<br/>[[File:Pipe-type-virtual-tee.png|350 px|center|thumb|5. Virtual pipe-runs at connections with U-fittings]]<br clear="all"/>
#* W systemie tworzącym podłączenia za pośrednictwem U-kształtek, program automatycznie nada typ rury "wirtualny" dla działek tworzących podejścia do odbiorników.
#* In the system of forming connections via the U-fittings, the program will automatically set the type of pipe-run "virtual" for the pipe-runs comprising approaches to the receivers.
#* Zamyknąć pierścień instalacji.<br/><span style="color: cornflowerblue">Więcej na temat ''Podłączania odbiorników'': ''[[Podłączanie odbiorników]]<!--Case xxxxx-->''</span>.''<br/>
#* Close the ring.<br/><span style="color: cornflowerblue">More about ''Connecting the receivers'': ''[[Connecting the receivers]]<!--Case xxxxx-->''</span>.''<br/>





Revision as of 11:59, 27 August 2014

Product InstalSystem 4
Type of article Software application
Content up-to-date for version IS 4.13

Range of lesson

The following lesson demonstrates how make installation of the water supply system in Instal-san T, using the ring system.
The installation is located in a two-storey public utility building with basement.

Modules and program configuration

  • Instal-san T allows to make a project of the water supply system.
  • catalogs containing the most suitable for the ring installations connections systems:
    • U-fittings system with direct plugging of a tap to the U-fitting for looping or
    • system with direct plugging of a tap to the U-fitting for looping

Inital state

The file in an initial state takes into account the graphical presentation of the ground and the floor, shown in two separate sheets.
More about editing the structure: Graphical presentation of the building structure.
The file also contains a piece of the water supply including inserted receivers and water supply stacks. Tips on how to make such a basic file are contained in the article Design of water installation - basics.

Steps to perform

Running application and configuration of basic project data

  1. Run the program Instal-san T.
  2. Load the file with the prepared structure of the building and fragment of installation including receivers and water supply stacks.


Inserting the pipe-runs of utility water

  1. Put on every storey the pipe-runs of cold tap water and hot tap water in the form of a open ring surrounding powered receivers. The program will allow for the closure of the ring after connecting the receivers.
    1. Not fully closed ring of utility water pipe-runs


Connecting the receivers

  1. Connections to the receivers by U-fittings system with direct inclusion tap to the T-fitting:
    • Highlight a piece of installation, to take into account the receivers and the pipe-runs want to connect to, and then select the key combination Shift + Ctrl + A or an option "Automatically connect terminal units" available in menu for Components.
      2. Receivers connect by T-fittings

      3. Virtual pipe-runs in connections with T-fittings

    • In U-fittings system, after selecting "Automatically connect terminal units", give the type of pipe-run "virtual" for the pipe-runs comprising approaches to the receivers.
    • Close the ring.
  2. Connecting the receivers in the system of direct inclusion of tap for the U-fitting:
    • Select the part of the installation, to take into account the receivers and the pipe-runs want to connect to, and then select the key combination Shift + Ctrl + L or an option "Receptor connect automatically with U-Fitting for looping" available in menu for Components.
      4. Receivers connected using U-fittings

      5. Virtual pipe-runs at connections with U-fittings

    • In the system of forming connections via the U-fittings, the program will automatically set the type of pipe-run "virtual" for the pipe-runs comprising approaches to the receivers.
    • Close the ring.
      More about Connecting the receivers: Connecting the receivers.


Utworzenie rozwinięcia instalacji

  1. Jeżeli w projekcie występuje cyrkulacja, powinna być ona zakończona przed pierścieniem.
    6. Armatura

  2. Pozostałe fragmenty rozwinięcia instalacji utworzyć w sposób standardowy.

Final state

Poniżej załączono plik wynikowy:

Plik projektu, Instal-san T: <br\>Plik:Instal-san-t-example-of-ring-installation.ISB

More about hot to download the file: Downloading and calculating file from HelpSystem.