* The additional sewage pipe should be connected to the sewage collector at least 2 m from the base of the stack;
* The additional sewage pipe should be connected to the sewage collector at least 2 m from the base of the stack;
* ''<IS_TS id=LacznikiNaKazdejKondygnacji/>'' is declared as well;
* ''<IS_TS id=LacznikiNaKazdejKondygnacji/>'' is declared as well;
* The connection of the additional stack to the main stack is made automatically by the means of a "vent loop". {{Info}} [[Creating pressure-relief loops in high-rise stacks of sanitary sewage installations]].<br/>[[File:Sewage installations Bypass ventilation Schema E.png|900 px|left|thumb|5. Schema E.]]<br clear="all"/>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_E.isproj Bypass ventilation Schema E, isproj]
* The connection of the additional stack to the main stack is made by the means of a "vent loop". {{Info}} [[Creating pressure-relief loops in high-rise stacks of sanitary sewage installations]].<br/>[[File:Sewage installations Bypass ventilation Schema E.png|900 px|left|thumb|5. Schema E.]]<br clear="all"/>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_E.isproj Bypass ventilation Schema E, isproj]
The attached projects present an exemplary solutions for a sewage installation with bypass ventilation. Schemes A-D are applicable to buildings from 3 to 5 floors (less or equal to 12m in height). Schema E - for the buildings with more than 5 floors (more than 12m in height).
Files to download and project information
Schema A
Direct parallel ventilation: vent stack is connected to the sewage stack at the bottom near the stack foot, and at the top to the vent pipe;
Indirect parallel ventilation: vent stack is a separate one, and is connected to the branches on each floor. Horizontal ventilation pipes are to be drawn manually, correcting the elevation where necessary;