Sewage installations - Bypass ventilation: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
No edit summary
Line 48: Line 48:
** ''<IS_TS id=LacznikiNaKazdejKondygnacji/>'' is declared as well;
** ''<IS_TS id=LacznikiNaKazdejKondygnacji/>'' is declared as well;
** The connection of the additional stack to the main stack is made by the means of a "vent loop". <br/>[[File:Bypass ventilation schema E.png |900 px|left|thumb|6. Schema E.]]<br clear="all"/>
** The connection of the additional stack to the main stack is made by the means of a "vent loop". <br/>[[File:Bypass ventilation schema E.png |900 px|left|thumb|6. Schema E.]]<br clear="all"/>
 
==Files to download==
[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_A.isproj Bypass ventilation Schema A, isproj]</br>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_B.isproj Bypass ventilation Schema B, isproj]</br>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_C.isproj Bypass ventilation Schema C, isproj]</br>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_D.isproj Bypass ventilation Schema D, isproj]</br>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_E.isproj Bypass ventilation Schema E, isproj]


<!--Specify the list of categories of commercial products, which the article concerns-->
<!--Specify the list of categories of commercial products, which the article concerns-->

Revision as of 10:19, 6 July 2023

Product InstalSystem 5
Type of article FUNCTION AND TOOL
Source for translation 2023-06-21


Description

The article describes methods of implementation of various cases of bypass ventilation in sewage installations.

Location in the program

In many cases of bypass ventilation the internal structure of stacks should be changed. This is achieved by modifying stack data: types of pipes inside, declaration of elements on the top, declaration of internal connections, etc.

The type of the stack is indicated in the Data table.

1. Pipe-run types.


All necessary points should be specified. Some geometrical data (distances between internal connections) have default values, but these may not fit all cases and often require manual correction after observing the 3D model.

Example of use

The program provides several schemes of bypass ventilation. Please note, that all changes inside the stack can be achieved only by changing stack data (no graphical edition possible). After drawing and connecting a ventilation pipe-run to a sewage pipe-run, manual correction of the elevations may be necessary. Schemes A-D are applicable to buildings from 3 to 5 floors (less or equal to 12m in height). Schema E - for the buildings with more than 5 floors (more than 12m in height).

  • Schema A:
    • Direct parallel ventilation: vent stack is connected to the sewage stack at the bottom near the stack foot, and at the top to the vent pipe;
    • Generate intermediate ventilation connections can be made or not depending on the project features.
      2. Schema A.

  • Schema B:
    • Indirect parallel ventilation: vent stack is a separate one, and is connected to the branches on each floor. Horizontal ventilation pipes are to be drawn manually, correcting the elevation where necessary;
    • Air admittance valve is used as an Element on top of stack for both stacks (Sanitary drainage and Ventilation conduit).
      3. Schema B.

  • Schema С:
    • Direct parallel ventilation: vent stack is connected to the sewage stack at the bottom near the stack foot and at the top to the vent pipe;
    • Generate intermediate ventilation connections are made;
    • Connection to the vent stack from each fixture on the first floor and from each sewage branch on the floors above.
      4. Schema C.

  • Schema D:
    • Air admittance valve is used on the first floor for the most distant fixture;
    • Drainage ventilating pipe-run are connected to the sewage stack on the floors above.
      5. Schema D.

  • Schema E:
    • In high buildings the fixtures on the lowest floors should be connected to the additional sewage pipe in the stack;
    • The additional sewage pipe should be connected to the sewage collector at least 2 m from the base of the stack;
    • Generate intermediate ventilation connections is declared as well;
    • The connection of the additional stack to the main stack is made by the means of a "vent loop".
      6. Schema E.