==Description==
==Description==
The article describes the usage of the ''<IS_TS id=iNameCOZbiornikBuforowySystemowMieszkaniowychWezlowCWU/>'' - the element of ''<IS_TS id=InstalacjeGrzewcze/>'', ''<IS_TS id=InstalacjeChlodnicze/>'' and ''<IS_TS id=InstalacjeWodociagowe/>'' that is used in to accumulate heating energy and distribute it evenly. The introduction of a ''<IS_TS id=iNameCOZbiornikBuforowySystemowMieszkaniowychWezlowCWU/>'' into a building's engineering installations allows significant savings in energy resources.</br>
The article describes the usage of the ''<IS_TS id=iNameCOZbiornikBuforowySystemowMieszkaniowychWezlowCWU/>'' - the element of ''<IS_TS id=InstalacjeGrzewcze/>'' or ''<IS_TS id=InstalacjeChlodnicze/>''. In the program it has two primary and two secondary connections (supply and return).
In the program, the ''<IS_TS id=iNameCOZbiornikBuforowySystemowMieszkaniowychWezlowCWU/>'' is represented as a free-standing item. When using it, it is important to remember to include a pump in the secondary circuit.


==Location in the program==  
==Location in the program==  

Revision as of 12:49, 21 January 2023

Product InstalSystem 5
Type of article FUNCTION AND TOOL
Source for translation 2023-01-17


Description

The article describes the usage of the Buffer tank - the element of Heating systems or Cooling systems. In the program it has two primary and two secondary connections (supply and return).

Location in the program

The Buffer tank icon can be found in the 2D Editor window on the Main tools toolbar in Convectional and Rad.-floors,walls sections:

1. Insert Buffer tank.


Example of use

Placing the component

After placing the Buffer tank at the desired location on the drawing the following data should be entered in the Data table window:

  • Distance from floor (set in storey data)
  • Type (Important: for the Fittings not from catalogue indicate Orientation, Connection diam. and the value of Water capacity (V))
    2. Data table.

Connecting the component

  1. After all system components have been placed on the drawing the Buffer tank should be connected to the source on one side (primary circuit) and to the system on the other side (secondary circuit). Connection to the Buffer tank is made by using Supply and Return pipelines.
  2. A Pump needs to be installed on the secondary side.

Additional information

After running calculations the information on the type of the Buffer tank and the Pump can be found in the Results window.

3. Results window.