When working on a less powerful graphics card, the calculation time, which also includes the time necessary for refreshing of the drawing of the building model and the installation after calculation, may be reduced noticeably after disabling the ''<IS_TS id=View3D/>'' window. <br/>[[File:View3D.png|1100px|left|thumb|3. Disabling the ''<IS_TS id=View3D/>'' window]]<br clear="all"/>
When working on a less powerful graphics card, the calculation time, which also includes the time necessary for refreshing of the drawing of the building model and the installation after calculation, may be reduced noticeably after disabling the ''<IS_TS id=View3D/>'' window. <br/>[[File:View3D.png|1100px|left|thumb|3. Disabling the ''<IS_TS id=View3D/>'' window]]<br clear="all"/>


===Wyłączenie funkcji ''<IS_TS id=GenerujRysunkiPetli/>''===
===Disabling the ''<IS_TS id=GenerujRysunkiPetli/>'' function===
Dotyczy modułu ''<IS_TS id=PH_IS5_RL/>''. Jeśli rysunki pętli nie są wymagane lub jeśli zostały już wygenerowanu i uzyskano zadowalające efekty można wyłączyć ich generowanie zgodnie z:  
This applies to the ''<IS_TS id=PH_IS5_RL/>'' module. If loop drawings are not required or if they have already been generated and satisfactory results have been obtained, their generation can be disabled as described in:  
{{Info}} [[Appending drawings with radiant system loops#Manual editing of loop drawings|Manual editing of loop drawings]].<br/>[[File:Generate_loops_drawings.png|1100px|left|thumb|4.Generowanie rysunków pętli.]]<br clear="all"/>
{{Info}} [[Appending drawings with radiant system loops#Manual editing of loop drawings|Manual editing of loop drawings]].<br/>[[File:Generate_loops_drawings.png|1100px|left|thumb|4.Generating loop drawings.]]<br clear="all"/>


===Wyłączenie automatycznego podziału elementu ''<IS_TS id=strSPGCh/>'' i rysowania przyłączy===
===Wyłączenie automatycznego podziału elementu ''<IS_TS id=strSPGCh/>'' i rysowania przyłączy===

Revision as of 15:13, 30 December 2021

Product InstalSystem 5
Type of article TIP&TRICK
Source for translation 2021-12-08


Problem description

In the case of elaborate projects the time of completing calculations for all active calculation modules can extend to several tens of seconds or even several minutes. However, it is possible to control what scope of the project is being calculated and what actions are to be performed by the program during their duration.

Solution

Running selected calculations only

Clicking the button results in all project scopes being calculated by default. The calculation time can be shortened by doing one of the following:

  1. Disabling indicated calculation scopes by unchecking checkboxes adjacent to the relevant module icons upon expanding the button.
    1. Thermal calculations of building
    2. Computation of building structure
    3. Calculations of Heating and cooling systems
    4. Calculations of Water supply systems
    5. Calculations of Drainage systems
  2. Running calculations of a selected project scope only by clicking the relevant icon
  3. Excluding selected modules from the project scope in the General data window


1.Running selected calculation scopes only.



For more information, see: Calculations and diagnostics

Change program settings

Do not enable automatic switching to the Results window after completing calculations. This will reduce the calculations time by the time needed for switching to the Results and for refreshing the printout.

2.Changing program settings.


Disabling the 3D window

When working on a less powerful graphics card, the calculation time, which also includes the time necessary for refreshing of the drawing of the building model and the installation after calculation, may be reduced noticeably after disabling the 3D view window.

3. Disabling the 3D view window


Disabling the Generate loops drawings function

This applies to the Radiant systems module. If loop drawings are not required or if they have already been generated and satisfactory results have been obtained, their generation can be disabled as described in:

For more information, see: Manual editing of loop drawings.

4.Generating loop drawings.


Wyłączenie automatycznego podziału elementu Heating/Cooling Zone i rysowania przyłączy

Dotyczy modułu Radiant systems. Z uwagi na konieczność uwzględnienia wielu parametrów, algorytm podziału elementu Heating/Cooling Zone i rysowania przyłączy mogą w znaczący sposób wydłużyć czas obliczeń projektu dla zakresu Heating and cooling systems. Po uzyskaniu zadowalających wyników (hydraulicznych, cieplnych i graficznych) możliwe jest wyłączenie tych algorytmów.
For more information, see: Dividing a Heating/Cooling Zone into Heating-cooling surface components

Inne

Jeśli w projekcie użyto różnych systemów rur i kształtek, dobór połączeń między systemami może trwać dłużej przy pierwszym przeliczeniu projektu.