How to eliminate: "Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually": Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
| Line 12: | Line 12: | ||
|c3 =<!--Jest kategoria -> zamienić na: "category3=" i uzupełnić link do sekcji kategorii na stronie głównej produktu--> | |c3 =<!--Jest kategoria -> zamienić na: "category3=" i uzupełnić link do sekcji kategorii na stronie głównej produktu--> | ||
|category_name3 =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...--> | |category_name3 =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...--> | ||
|version1 = | |version1 =2020-01-09 | ||
|v2 =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu--> | |v2 =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu--> | ||
|v3 =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu--> | |v3 =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu--> | ||
Revision as of 18:20, 19 May 2021
| Product | InstalSystem 5 |
| Type of article | TYPICAL PROBLEM |
| Source for translation | 2020-01-09 |
Problem description
Problems associated with automatic generation of pipe feeds using the Pipe feeds route tool are diagnosed by means of the following message:
- Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually.
The message informs that pipe feeds could not be generated automatically by means of the Pipe feeds route tool, due to the following reasons:
- specified or automatically sized arrangement spacings are too large,
- manner of component crossing Pipe feeds route is inappropriate (for the algorithm of automatic pipe feed arrangement),
- number of component crossings Pipe feeds route is too large,
- Pipe feeds route components are located too close to each other,
- width of the strip within which Pipe feeds route generates pipe feeds is too small or too large (reaches beyond the borders of the heating zone).
Solution
- Specify smaller pipe feed arrangement spacing.
- Change manner of Pipe feeds route component arrangement.
- Increase width of Pipe feeds route component arrangement area.
- Draw pipe feeds manually.
Depending on design circumstances, or when pipe feeds cannot be generated automatically, the tool for manual arrangement of pipe feeds can be used.
For more information, see: Manual pipe feeds editing.