| Line 19: | Line 19: | ||
==Description== | ==Description== | ||
When creating | When creating [[Preparation_of_building_structure_-_Complete_building_structure | Complete building structure]], including the [[BIM_-_Interpretation_of_IFC_elements_into_building_structure_elements_of_InstalSystem_5_package | Building structure based on an IFC model]] the drawing inaccuracies may arise. This results in minor misalignments between structural elements (such as walls) located on consecutive storeys. In turn, these may lead to an incorrect interpretation of the building structure. In order to avoid difficult and time-consuming manual corrections to the structural model, we propose to use the tools that automatically correct the wall geometry. | ||
By using the ''<IS_TS id=CorrectWallGeometry/>'' | By using the ''<IS_TS id=CorrectWallGeometry/>'' and ''<IS_TS id=CorrectWallConnections/>'' functions such artifacts can be eliminated and proper building structure can be obtained. | ||
<br>[[File:Wall geometry correction tool bar.png |1100 px|left|thumb|1. Using the <IS_TS id=CorrectWallGeometry/> tool.]]<br clear="all"/> | <br>[[File:Wall geometry correction tool bar.png |1100 px|left|thumb|1. Using the <IS_TS id=CorrectWallGeometry/> tool.]]<br clear="all"/> | ||
| Line 29: | Line 29: | ||
*** intersecting walls, | *** intersecting walls, | ||
*** walls nested within one another. | *** walls nested within one another. | ||
'''''Note:''''' We strongly recommend using this function after making | '''''Note:''''' We strongly recommend using this function after making , before proceeding with further editing or running ''<IS_TS id=BuildingStructureCalculation/>''. | ||
* ''<IS_TS id=CorrectWallThickness/>'' - to standardize wall thicknesses to specified thickness variants | * ''<IS_TS id=CorrectWallThickness/>'' - to standardize wall thicknesses to specified thickness variants | ||
* ''<IS_TS id=CorrectWallAngles/>'' - to fix the angles between connected walls | * ''<IS_TS id=CorrectWallAngles/>'' - to fix the angles between connected walls | ||
Revision as of 11:27, 14 September 2026
| Product | InstalSystem 5 |
| Type of article | FUNCTIONS AND TOOLS |
| Source for translation | 2026-09-09 |
Description
When creating Complete building structure, including the Building structure based on an IFC model the drawing inaccuracies may arise. This results in minor misalignments between structural elements (such as walls) located on consecutive storeys. In turn, these may lead to an incorrect interpretation of the building structure. In order to avoid difficult and time-consuming manual corrections to the structural model, we propose to use the tools that automatically correct the wall geometry. By using the Correction of wall geometry and Correct wall connections functions such artifacts can be eliminated and proper building structure can be obtained.

The Correction of wall geometry tool can be used for the following purposes:
- Correct wall connections:
- to rectify wall connections if these were not made correctly with the Automatic walls, slabs and roofs function.
- to correct issues that arise particularly frequently when interpreting IFC models:
- intersecting walls,
- walls nested within one another.
Note: We strongly recommend using this function after making , before proceeding with further editing or running Computation of building structure .
- Correct wall thickness - to standardize wall thicknesses to specified thickness variants
- Correct angles of the walls - to fix the angles between connected walls
- Correct position between storeys - to align the positions of walls located one above the other on successive storeys
Examples of use
The Correction of wall geometry tool has four options:
- Correct wall connections
- Correct wall thickness - enables specifying/removing a permissible wall thickness. The Correct wall thickness tool standardizes the Thickness of a Wall to a defined value across the entire project.
- Correct angles of the walls - specifies the value of angle correction of a Wall. The Correct angles of the walls function modifies the value to a grid value, which by default is set to 3. The value is complemented to 90, 93, 96 and so on and adjusted accordingly. The angle shift does not depend on the position of the wall hotpoint.
- Correct position between storeys requires specifying the tolerance (in cm) of the mutual vertical misalignment of Wall type components. The storey with respect to which the alignment correction is to be made must also be indicated. ATTENTION! This function corrects the position of walls only, corrections in the area of horizontal slab partitions, if required, must be made manually.
| If you have any comments on this article, please send us a short message at info@instalsoft.com. |
|---|