Linear and point thermal bridges: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
No edit summary
Line 37: Line 37:
#** ''<IS_TS id=rsEN12831_DodatekNaMostkiZUwzlednieniemMostkow/>'' - ''<IS_TS id=sENPrzegrodadU0_NaMostkiPNEN/>'' = 0.1 <IS_TS id=_rssWsp_kPowierzchniowyInSI/>''.  
#** ''<IS_TS id=rsEN12831_DodatekNaMostkiZUwzlednieniemMostkow/>'' - ''<IS_TS id=sENPrzegrodadU0_NaMostkiPNEN/>'' = 0.1 <IS_TS id=_rssWsp_kPowierzchniowyInSI/>''.  
===Scenario II - <IS_TS id=rsEN12831_MetodaUwzglednianiaMostkowCieplnychEN12831/> method of accounting linear thermal bridges===
===Scenario II - <IS_TS id=rsEN12831_MetodaUwzglednianiaMostkowCieplnychEN12831/> method of accounting linear thermal bridges===
''<IS_TS id=rsEN12831_MetodaUwzglednianiaMostkowCieplnychEN12831/>''


==ADDITIONAL INFORMATION==  
==ADDITIONAL INFORMATION==  

Revision as of 08:46, 25 April 2025

Product InstalSystem 5
Type of article FUNCTION AND TOOL
Source for translation 2025-04-22


DESCRIPTION

This article describes methods of accounting linear and point thermal bridges in thermal calculations of partitions and building structures.

LOCATION IN THE PROGRAM

The selection of the Thermal bridges calculation method is available in the General data window, Calculation standards and options tab.

1. Thermal bridges calculation method.


EXAMPLE OF USE

Scenario I - Simplified method of accounting linear thermal bridges

  1. Editing the default data:
    • In the General data window choose Simplified for the Thermal bridges calculation method. Note: this method is available for the EN standards;
    • (Optionally) Set auto mode for the Manner of making allowance for thermal bridges. This causes the auto mode status to be set for all fields of the ΔUtb (Allowance for thermal bridges) column, available on the form Building structure / Building (rooms view), with the following default values:
      • ΔUtb = 0.05 W/(m2·K) - for the external partitions (EW, EWi, ED, EF, RO) and for thr partitions in contact with the ground (WG, FL);
      • ΔUtb = 0.00 W/(m2·K) - for the internal partitions (IW, IF, ID, IWi).
        2. ΔUtb column with "auto mode" status.

    • (Optionally) Introducing ΔU - available for the DIN standards.
  2. Editing the Room data:
    • Select the method of determine ΔUtb (Allowance for thermal bridges) in the form Building structure / Building (rooms view):
      3. Allowance for thermal bridges.

      • User's - allows to set the value of the allowance by yourself;
      • Automaticaly - initialises the default values according to the auto mode;
      • Without accounting for thermal bridges in construction terms - ΔUtb = 0.05 W/(m2·K);
      • Accounting for thermal bridges in construction terms - ΔUtb = 0.1 W/(m2·K).

Scenario II - Acc. to EN 12831 method of accounting linear thermal bridges

Acc. to EN 12831