==Problem description== | ==Problem description== | ||
After the automatic generating of a schematic view of the installation in some cases its modification is required. | After the automatic generating of a schematic view of the installation in some cases its modification is required. This article describes how to modify the ''<IS_TS id=strKolejnoscRozwijaniaCaption/>'' and how to reduce gaps in the pipeline sections with the use of ''<IS_TS id=rpCreateSchematicGuide/>''. | ||
==Solution== | ==Solution== | ||
Revision as of 07:49, 31 October 2023
| Product | InstalSystem 5 |
| Type of article | TIP&TRICK |
| Source for translation | 2023-10-24 |
Problem description
After the automatic generating of a schematic view of the installation in some cases its modification is required. This article describes how to modify the Order of installation fragments and how to reduce gaps in the pipeline sections with the use of Control point.
Solution
Use Control point to:
- Modify the Order of installation fragments - the connection order for high-temperature collectors .
Note: to specify the fragment of the installation to be generated use the Starting point and the Endpoint.
- Reduce gaps in the pipeline sections.
To modify the elevation of the pipe-runs use the functions:
- Vertical layout of pipe-run,
- Elevation,
- Distance from floor (set in storey data).