Checklist for verifying thermal partitions: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
No edit summary
 
(8 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<!--Case 329325-->
<IS_HELP id="HS205"/>
{{Article table
{{Article table
|commercial_product1=InstalSystem 5
|commercial_product1=InstalSystem 5
Line 10: Line 12:
|c3                =<!--Jest kategoria -> zamienić na: "category3=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|c3                =<!--Jest kategoria -> zamienić na: "category3=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|category_name3    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|category_name3    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|version1          =2025-09-08
|version1          =2026-04-07
|v2                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
|v2                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
|v3                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
|v3                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
Line 20: Line 22:


==Solution==
==Solution==
# On ''<IS_TS id=View3D/>'' in the  ''<IS_TS id=ScopeOZC_T_Short/>'' (''<IS_TS id=ScopeOZC/>'') scope '''analyze the completeness of partitions in the thermal model'''. For the best result turn the visibility of the ''<IS_TS id=ScopeOZC_T_Short/>'' scope to the ''<IS_TS id=stringZakresEdycjiOnlyActive/>'' using the right mouse button context menu;[[File:Checklist for verifying thermal partitions H&E(T) visibility.png|900 px|left|thumb|1. Verifying thermal partitions / H&E(T) visibility.]]<br clear="all"/>
# On ''<IS_TS id=View3D/>'' in the  ''<IS_TS id=ScopeOZC_T_Short/>'' (''<IS_TS id=ScopeOZC/>'') scope '''analyze the completeness of partitions in the thermal model'''. For the best result turn the visibility of the ''<IS_TS id=ScopeOZC_T_Short/>'' scope to the ''<IS_TS id=stringZakresEdycjiOnlyActive/>'' using the right mouse button context menu;<br/>[[File:Checklist H&E(T) visibility.png|900 px|left|thumb|1. Verifying thermal partitions / H&E(T) visibility.]]<br clear="all"/>
# If fragments are missing, check if the corresponding ''<IS_TS id=iNameKonstrPomieszczeniePlural/>'' are automatic and whether they have closed contours;
# If fragments are missing, check if the corresponding ''<IS_TS id=iNameKonstrPomieszczeniePlural/>'' are automatic and whether they have closed contours;
# Check whether a zero-thickness wall has been pasted between the rooms if you expect a thermal partition there;
# If a thermal partition is not created where you expect it, check whether there is a zero-thickness wall between the rooms.;
# '''For  <IS_TS id=Roof/> and <IS_TS id=Lukarna/>:''' ensure that the ''<IS_TS id=Roof/>'' covers the ''<IS_TS id=ObrysBud/>'' and is modeled correctly (roof edges, sections, levels). Improve, if necessary, and run the ''<IS_TS id=BuildingStructureCalculation/>'';
# '''For  <IS_TS id=Roof/> and <IS_TS id=Lukarna/>:''' ensure that the ''<IS_TS id=Roof/>'' covers the ''<IS_TS id=ObrysBud/>'' and is modeled correctly (roof edges, sections, levels). Improve, if necessary, and run the ''<IS_TS id=BuildingStructureCalculation/>'';
# '''For <IS_TS id=sBudynek/> embedded below ground level when using the <IS_TS id=Grunt/> element,''' check the boundary between the ''<IS_TS id=rsTypKonstrukcjiPrzegrodyScianaZewnetrzna/>'' and ''<IS_TS id=rsTypKonstrukcjiPrzegrodyScianaPrzyGruncie/>'' partition types, which is indicated by the ground contour around the ''<IS_TS id=sBudynek/>'';
# '''For <IS_TS id=sBudynek/> embedded below ground level when using the <IS_TS id=Grunt/> element,''' check the boundary between the ''<IS_TS id=rsTypKonstrukcjiPrzegrodyScianaZewnetrzna/>'' and ''<IS_TS id=rsTypKonstrukcjiPrzegrodyScianaPrzyGruncie/>'' partition types, which is indicated by the ground contour around the ''<IS_TS id=sBudynek/>'';
# <!-- will be added after release 29.0 is realized in accordance with the case https://it.instalsoft.com/default.asp?329325 p.2.6 -->
# For more precise verification of the created thermal model, the section ''<IS_TS id=PartitionsVisibility/>'', located on the working menu and on the status bar for the ''<IS_TS id=ScopeOZC_T_Short/>'' scope, can be used. The functions operate simultaneously in ''<IS_TS id=GraphicalEdit/>'' and on ''<IS_TS id=View3D/>''. </br> The following selection of partition visibility, grouped by their location in the building, is available:
 
#* ''<IS_TS id=ShowOnlyHorizontalPartitions/>'',
#* ''<IS_TS id=ShowOnlyVerticalPartitions/>'',
#* ''<IS_TS id=ShowOnlyExternalPartitions/>'',
#* ''<IS_TS id=ShowOnlyInternalPartitions/>'',
#* ''<IS_TS id=ShowAllPartitions/>''. </br>[[File:Checklist for verifying thermal partitions partitions visibility.png|900 px|left|thumb|2. <IS_TS id=PartitionsVisibility/>.]]<br clear="all"/>


[[Category:InstalSystem 5]]
[[Category:InstalSystem 5]]
[[Category:TIP&TRICK]]
[[Category:TIP&TRICK]]
<!-- Do not write text below this tag -->
<br class="iwlinks"/>[[pl:Lista kontrolna do weryfikacji przegród termicznych|Lista kontrolna do weryfikacji przegród termicznych]]

Latest revision as of 12:26, 21 April 2026


Product InstalSystem 5
Type of article TIP&TRICK
Source for translation 2026-04-07


Problem description

For the precise Thermal calculations of building and generating of the Thermal model of a building (For more information, see: Calculation of design heat load of rooms), it's very important to verify automatic thermal partitions, created based on structural elements and automatically recognized Rooms, especially in cases of complex geometry (multi-pitched Roof, Dormer).

Solution

  1. On 3D view in the H&E(T) (Thermal partitions in heat transmission calculations) scope analyze the completeness of partitions in the thermal model. For the best result turn the visibility of the H&E(T) scope to the The only one visible when active using the right mouse button context menu;
    1. Verifying thermal partitions / H&E(T) visibility.

  2. If fragments are missing, check if the corresponding Rooms are automatic and whether they have closed contours;
  3. If a thermal partition is not created where you expect it, check whether there is a zero-thickness wall between the rooms.;
  4. For Roof and Dormer: ensure that the Roof covers the Building contour and is modeled correctly (roof edges, sections, levels). Improve, if necessary, and run the Computation of building structure ;
  5. For Building embedded below ground level when using the Ground element, check the boundary between the External wall and Wall near the ground partition types, which is indicated by the ground contour around the Building;
  6. For more precise verification of the created thermal model, the section Partitions visibility, located on the working menu and on the status bar for the H&E(T) scope, can be used. The functions operate simultaneously in 2D editor and on 3D view.
    The following selection of partition visibility, grouped by their location in the building, is available:
    • Show horizontal partitions only,
    • Show vertical partitions only,
    • Show external partitions only,
    • Show internal partitions only,
    • Show all partitions.
      2. Partitions visibility.