Sewage installations - Bypass ventilation: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
No edit summary
No edit summary
 
(43 intermediate revisions by 4 users not shown)
Line 1: Line 1:
<IS_HELP id="HS167"/>
{{Article table
{{Article table
|commercial_product1=InstalSystem 5
|commercial_product1=InstalSystem 5
Line 4: Line 5:
|p3                =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy3="-->
|p3                =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy3="-->
|p4                =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy3="-->
|p4                =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy3="-->
|category1          =InstalSystem 5#Functionalities
|category1          =InstalSystem 5#Sample project
|category_name1    =FUNCTION AND TOOL
|category_name1    =SAMPLE PROJECT
|c2                =<!--Jest kategoria -> zamienić na: "category2=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|c2                =<!--Jest kategoria -> zamienić na: "category2=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|category_name2    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|category_name2    =<!--podać nazwę kategorii, np.: ZASTOSOWANIE/FUNKCJONALNOŚĆ/...-->
|c3                =<!--Jest kategoria -> zamienić na: "category3=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|c3                =<!--Jest kategoria -> zamienić na: "category3=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|category_name3    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|category_name3    =<!--podać nazwę kategorii, np.: ZASTOSOWANIE/FUNKCJONALNOŚĆ/...-->
|version1          =2023-06-21
|version1          =2024-06-10
|v2                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link:
|v2                =
                        IS4 -> "[https://instalsoft.com/pl/produkty/informacje-o-zmianach-w-instalsystem.html <numer wersji>]" /
|v3                 =
                        NS4 -> "[https://instalsoft.com/pl/produkty/informacje-o-zmianach-w-netsystem.html <numer wersji>]" /
|v4                 =
                        IS5 -> "[[<link do sekcji RN danego produktu>|<numer wersji>]]"-->
|v3=
|v4=
}}
}}


==Description==
==Project description==
''Section for a description of function and tool, which should take into account:''
The attached projects present an exemplary solutions for a sewage installation with bypass ventilation.<br/>Schemes A-D are applicable to buildings from 3 to 5 floors (less or equal to 12m in height).<br/>Schema E - for the buildings with more than 5 floors (more than 12m in height).
* ''what it is (function/module) and what is it for,''
* ''how it works,''
* ''typical use (it is not necessary to list all function uses, only typical one) ''
''The section allows to add screenshots. They should explicitly adjust the selected element, eg. by marking the ellipse.''


==Videos related to the article==
==Files to download and project information==
''SEKCJA OPCJONALNA. <br/>
===Schema A===
''Należy ją dodać do artykułu w sytuacji gdy w playlistach na naszym kanale youtube dostępny jest webinar, w którym opisano działanie funkcji/narzędzia. Treść sekcji:''<br/>
* Direct parallel ventilation: vent stack is connected to the sewage stack at the bottom near the stack foot, and at the top to the vent pipe;
/link do filmu zgodnie z [[Template:Embed_video]]/<br clear="all"/>
* ''<IS_TS id=LacznikiNaKazdejKondygnacji/>'' can be made or not depending on the project features.<br/>[[File:Bypass ventilation schema A.png|900 px|left|thumb|1. Schema A.]]<br clear="all"/>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_A.isproj Bypass ventilation Schema A, isproj]</br>
===Schema B===
* Indirect parallel ventilation: vent stack is a separate one, and is connected to the branches on each floor. Horizontal ventilation pipes are to be drawn manually, correcting the elevation where necessary;
* ''<IS_TS id=pinNameZaworOdpLubNapow/>'' is used as an ''<IS_TS id=EndOfSewerageLine/>'' for both stacks (''<IS_TS id=strKanalizacjaSanitarna/>'' and ''<IS_TS id=strKanalizacjaWentylacja/>'').<br/>[[File:Bypass ventilation schema B.png|900 px|left|thumb|2. Schema B.]]<br clear="all"/>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_B.isproj Bypass ventilation Schema B, isproj]</br>
===Schema С===
* Direct parallel ventilation: vent stack is connected to the sewage stack at the bottom near the stack foot and at the top to the vent pipe;
* ''<IS_TS id=LacznikiNaKazdejKondygnacji/>'' are made automatically;
* Connection to the vent stack from each fixture on the first floor and from each sewage branch on the floors above.<br/>[[File:Bypass ventilation schema С.png|900 px|left|thumb|3. Schema C.]]<br clear="all"/>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_C.isproj Bypass ventilation Schema C, isproj]</br>


==Location in the program==  
===Schema D===
''Section describes how to use function|module:
* ''<IS_TS id=pinNameZaworOdpLubNapow/>'' is used on the first floor for the most distant fixture;
* ''where in the program is available,''
* ''<IS_TS id=iNameSanWentylacjaKanalizacji/>'' are connected to the sewage stack on the floors above.<br/>[[File:Bypass ventilation schema D.png |900 px|left|thumb|4. Schema D.]]<br clear="all"/>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_D.isproj Bypass ventilation Schema D, isproj]</br>
* ''how call the function (the toolbar, the function key, etc.).''
===Schema E===
* In high buildings the fixtures on the lowest floors should be connected to the additional sewage pipe in the stack;
* The additional sewage pipe should be connected to the sewage collector at least 2 m from the base of the stack;
* ''<IS_TS id=LacznikiNaKazdejKondygnacji/>'' is declared as well;
* The connection of the additional stack to the main stack is made automatically by the means of a "vent loop". <br/>[[File:Bypass ventilation schema E.png |900 px|left|thumb|5. Schema E.]]<br clear="all"/>[https://download.instalsoft.com/public/helpsystem/EN/SUF/Sewage-installations-Bypass-ventilation/ISPROJ/Bypass_ventilation_Schema_E.isproj Bypass ventilation Schema E, isproj]
<!-- Do not write text below this tag -->


==Example of use==
<!--Specify the list of categories of commercial products, which the article concerns-->
''Section containing the description of using the function - next steps.'' <br/>
''In this section you may fing a multiple examples of use, each of these examples is a separate point of this section.''<br/>
''They can be found in it such elements as:''<br/>
*''screenshots (clearly indicating element, eg. by selecting the ellipse). Screenshots should be align to the left side, in order to keep the appropriate indentation before inserting a screenshot is needed to put the mark ":". ''
*''A film or a reference to the film imaging use of the functions.''
''Warning! Acceptable is to give a few examples. Then each example is a separate section or point in the article).''


==Additional informations==
''Optional section that contains additional information describing the function/element of the program..''
<br/>


<!--Specify the list of categories of commercial products, which the article concerns-->
{|class="wikitable" style="width: 800px; margin: 0 auto;"
!If you have any comments on this article, please send us a short message at ''info@instalsoft.com''.
                 
|}


[[Category:InstalSystem 5]]
[[Category:InstalSystem 5]]
[[Category:FUNCTION AND TOOL]]
[[Category:SAMPLE PROJECT]]
 
<!-- Do not write text below this tag -->
<br class="iwlinks"/>[[pl:Kanalizacja grawitacyjna - wentylacja obejściowa|Kanalizacja grawitacyjna - wentylacja obejściowa]][[zh-cn:排水 - 通气管|排水 - 通气管]]

Latest revision as of 14:28, 11 July 2025

Product InstalSystem 5
Type of article SAMPLE PROJECT
Source for translation 2024-06-10


Project description

The attached projects present an exemplary solutions for a sewage installation with bypass ventilation.
Schemes A-D are applicable to buildings from 3 to 5 floors (less or equal to 12m in height).
Schema E - for the buildings with more than 5 floors (more than 12m in height).

Files to download and project information

Schema A

  • Direct parallel ventilation: vent stack is connected to the sewage stack at the bottom near the stack foot, and at the top to the vent pipe;
  • Generate intermediate ventilation connections can be made or not depending on the project features.
    1. Schema A.

    Bypass ventilation Schema A, isproj

Schema B

  • Indirect parallel ventilation: vent stack is a separate one, and is connected to the branches on each floor. Horizontal ventilation pipes are to be drawn manually, correcting the elevation where necessary;
  • Air admittance valve is used as an Element on top of stack for both stacks (Sanitary drainage and Ventilation conduit).
    2. Schema B.

    Bypass ventilation Schema B, isproj

Schema С

  • Direct parallel ventilation: vent stack is connected to the sewage stack at the bottom near the stack foot and at the top to the vent pipe;
  • Generate intermediate ventilation connections are made automatically;
  • Connection to the vent stack from each fixture on the first floor and from each sewage branch on the floors above.
    3. Schema C.

    Bypass ventilation Schema C, isproj

Schema D

  • Air admittance valve is used on the first floor for the most distant fixture;
  • Drainage ventilating pipe-run are connected to the sewage stack on the floors above.
    4. Schema D.

    Bypass ventilation Schema D, isproj

Schema E

  • In high buildings the fixtures on the lowest floors should be connected to the additional sewage pipe in the stack;
  • The additional sewage pipe should be connected to the sewage collector at least 2 m from the base of the stack;
  • Generate intermediate ventilation connections is declared as well;
  • The connection of the additional stack to the main stack is made automatically by the means of a "vent loop".
    5. Schema E.

    Bypass ventilation Schema E, isproj


If you have any comments on this article, please send us a short message at info@instalsoft.com.