Checklist for verifying thermal partitions

From HelpSystem
Revision as of 11:05, 8 September 2025 by Klintsevicho (talk | contribs) (Created page with "{{Article table |commercial_product1=InstalSystem 5 |p2 =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy2="--> |p3 =<!--...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Product InstalSystem 5
Type of article TIP&TRICK
Source for translation 2025-09-08


Problem description

Control point.

Solution

  1. On 3D view in the H&E(T) (Thermal partitions in heat transmission calculations) scope analyze the completeness of partitions in the thermal model. For the best result turn the visibility of the H&E(T) scope to the The only one visible when active using the right mouse button context menu;
  2. If fragments are missing, check if the corresponding Rooms are automatic and whether they have closed contours;
  3. Check whether a zero-thickness wall has been pasted between the rooms if you expect a thermal partition there;
  4. For the Roof and Dormer: ensure that the Roof covers the Building contour and is modeled correctly (roof edges, sections, levels). Improve, if necessary, and run the Computation of building structure ;