Heating/cooling zone build-up editor

From HelpSystem
Jump to navigation Jump to search




Template:Tabelka artykułu

Description

This article describes possibilities of editing structural, thermal and operational data of heating/cooling zones and structural partitions, upon which they are located.

Location in the program

Heating/cooling zone build-up editor is situated in: Data table after having ticked: Heating/Cooling Zone and checked the drop-down list Heating floor build-up \ Heating wall build-up \ Construction of heating/cooling ceiling.

1. Heating/cooling zone build-up


Example of use

Presentation of data in the heating/cooling zone build-up editor

  1. The Heating floor build-up \ Heating wall build-up \ Construction of heating/cooling ceiling field presents overall thickness of the heating/cooling zone as well as overall thermal resistance.
  2. Having opened the editor, the user gains access to particular data, on the basis of which overall values are calculated:
    • Overal thickness of heating/cooling zone layers.
      3. Layer thickness

    • Thermal resistance of particular layers of a given heating/cooling zone along with structural partition thermal resistance.
      4. Thermal resistance of layer


      5. Overall constructure thickness i Resistance of layers

After data modification in the editor window, it is necessary to recalculate the project to update all values.

Heating/Cooling zone build-up edition

Covering

6. Covering


  1. Default covering originates from General data for Room type elements.
    7. Default covering

  2. Covering may be changed for each Heating/Cooling Zone element.
    8. Covering


Overall thickness of the screed/plaster

9. Overall thickness of the screed/plaster



Overall thickness of the screed/plaster, in case of the Auto setting, may change according to the Max. working load value (), within limits allowed by the producer. The user may change thickness, also in the limits allowed by the system producer, while taking into consideration all other system data.
Thickness of the screed/plaster over the pipe Su is always calculated automatically by the program, and it cannot be changed manually.

Structural panel

10. Structural panel



The user may change the structural panel if:
  1. there are more structural panels than one for a given fastening method.
    11. Structural panel - wybór z General data


  2. In Data table of the element Heating/Cooling Zone, the user ticked off Std. general data - otherwise, the field is available only in the Auto status, with no edition possibilities.
    12. Structural panel - selection in Data table


Insulation option

13. Insulation option


  1. Auto
    Program dobiera Insulation option o minimalnym oporze wymaganym przez EN 1264: 1:2011 2:2013 3,4:2009 5:2008 dla wybranej płyty systemowej i na podstawie wartości Temperature on other side.
    14. Insulation option - Auto


  2. Manual
    Można wybrać gotowy Insulation option z katalogu lub zdefiniować własny wybierając poszczególne warstwy izolacji (do wyboru jest maksymalnie 5 warstw).
    15. Insulation option - Manual


Structure cross section drawing

Użytkownik może zmienić sposób prezentacji rysunku przekroju płaszczyzny grzewczo-chłodzącej.

16. Structure cross section drawing



Edycja danych konstrukcyjno-cieplnych przegród budowlanych

17. Dane konstrukcyjno-cieplne przegród budowlanych


  1. Program nie pobiera żadnych danych z elementów: Partition definitions z zakresu obliczeń: Thermal calculations of building i należy je skorygować ręcznie.
  2. Z okna: General data jest pobierana tylko wartość: Slab thickness.
    18. Slab thickness