Technical specification of NetSystem 4: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
No edit summary
No edit summary
Line 8: Line 8:
|c2                =<!--Jest kategoria -> zamienić na: "category2=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|c2                =<!--Jest kategoria -> zamienić na: "category2=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|category_name2    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|category_name2    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|c3                =<!--if there is the second category, change to->"category3="-->
|category_name3    =<!--fill up with category "SOFTWARE APPLICATION"/"FUNCTIONALITY"/...-->
|version1          =[http://instalsoft.com/en/products/information-about-changes-in-netsystem-package.html NS4.7]<!--uzupełnić link do sekcji RN danego produktu-->
|version1          =[http://instalsoft.com/en/products/information-about-changes-in-netsystem-package.html NS4.7]<!--uzupełnić link do sekcji RN danego produktu-->
|v2                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
|v2                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->

Revision as of 10:41, 4 September 2015

Product NetSystem 4
Type of article PRODUCT INFORMATION
Source for translation NS4.7


System-hardware requirements

  • operating system MS Windows 8, Windows 7, Vista, XP
  • 2 GHz dual core processor
  • 2 GB RAM for Win XP or 3 GB RAM for Win8, Win7 or Vista
  • minimum screen resolution 1280x1024
  • Microsoft.NET Framework 4 is required
  • Internet access for activation and updating of the software and directories is recommended
  • installation and later usage with the same user righs is recommended

List of standards and methods used for sizing and calculations

Net-san

Gravity sewerage network

  1. Flow stream for rainwater:
    • PN EN 752-4 Standard
    • Karl and Klauss R. Imhoff: Kanalizacja miast i oczyszczanie ścieków.
  2. Hydraulic calculations of partly filled pipes (Qs, Qd):
    • flow calculation due to Bretting’s formula.
    • pressure drop calculation due to Prandtl-Colebrook formula.
  3. Self-defecation:
    • due to the method of boundary shear stress.
  4. Pipe diameter sizing:
    • considering sum of flow values (Qs and Qd) and filling ratio.
  5. Network arrangement:
    • authorized method which meets required minimum and maximum depth gradient and collisions with other networks.
  6. Local pressure drops:
    • considering roughness of pipes taken from catalogue data or from ATV-DVWK A110P standard.

Pressure sewerage network

  1. Pumping stations:
    • based on: Karl and Klauss R. Imhoff: „Kanalizacja miast i oczyszczanie ścieków” and authorised method.
  2. Hydraulic calculations of completely filled pipes:
    • due to Colebrooke-White’s formula, Qs and Qd values are directly added up.
  3. Pipe diameter sizing:
    • considering vmax and Rmax values.
  4. Network arrangement:
    • authorized method.
  5. Local pressure drops:
    • not considered.

Water supply network

  1. Calculations of pipes completely filled:
    • due to Colebrooke-White’s formula.
  2. Pipe diameter sizing:
    • considering vmax and Rmax values.
  3. Network arrangement:
    • authorized method.
  4. Local pressure drops:
    • enabled by the ability of declaring dzeta value for knickpoints.