Wall geometry correction: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
Line 28: Line 28:


==Examples of use==
==Examples of use==
Tool ''<IS_TS id=CorrectWallGeometry/>'' has four options:
The ''<IS_TS id=CorrectWallGeometry/>'' tool has four options:
# ''<IS_TS id=CorrectWallConnections/>'' <br/>{{#ev:youtube|tNeITxLwaDk|900||||rel=0}} <br clear="all"/>  
# ''<IS_TS id=CorrectWallConnections/>'' <br/>{{#ev:youtube|tNeITxLwaDk|900||||rel=0}} <br clear="all"/>  
# ''<IS_TS id=CorrectWallThickness/>'' - możliwe jest dodanie/usunięcie dopuszczalnej grubości przegrody. Tool ''<IS_TS id=CorrectWallThickness/>'' unifikuje do określonych wartości ''<IS_TS id=strpnScianaGrubosc/>'' elementu ''<IS_TS id=iNameKonstrSciana/>'' w całym projekcie. <br/>{{#ev:youtube|wDNAkU44tTc|900||||rel=0}} <br clear="all"/>
# ''<IS_TS id=CorrectWallThickness/>'' - enables specifying/removing a permissible wall thickness. The ''<IS_TS id=CorrectWallThickness/>'' tool standardizes the ''<IS_TS id=strpnScianaGrubosc/>'' of a ''<IS_TS id=iNameKonstrSciana/>'' to a defined value across the entire project. <br/>{{#ev:youtube|wDNAkU44tTc|900||||rel=0}} <br clear="all"/>
# ''<IS_TS id=CorrectWallAngles/>'' - nadanie własnego kąta korekcji elementu ''<IS_TS id=iNameKonstrSciana/>''. Funkcja ''<IS_TS id=CorrectWallAngles/>'' modyfikuje wartość w stronę pełnej siatki kąta, która ustawiona jest domyślnie na wartość 3. Program dopełnia wartość na zasadzie 90, 93, 96 itd. i do tego wyrównuje. Przesunięcie kąta nie zależy od położenia hotpointa ściany. <br/>{{#ev:youtube|_Xy4aImUOng|900||||rel=0}} <br clear="all"/>
# ''<IS_TS id=CorrectWallAngles/>'' - specifies the value of angle correction of a ''<IS_TS id=iNameKonstrSciana/>''. The ''<IS_TS id=CorrectWallAngles/>'' function modifies the value to a grid value, which by default is set to 3. The value is complemented to 90, 93, 96 and so on and adjusted accordingly. The angle shift does not depend on the position of the wall hotpoint. <br/>{{#ev:youtube|_Xy4aImUOng|900||||rel=0}} <br clear="all"/>
# ''<IS_TS id=CorrectWallShifts/>'' wymaga zdefiniowania tolerancji (w cm) przesunięcia elementów typu ''<IS_TS id=iNameKonstrSciana/>'' względem siebie w układzie pionowym. Należy dodatkowo określić kondygnację względem której system wykona korektę położenia elementów. '''UWAGA!''' Funkcja koryguje wyłącznie położenie ścian, w razie konieczności należy ręcznie skorygować obszar stropu.
# ''<IS_TS id=CorrectWallShifts/>'' requires specifying the tolerance (in cm) of the mutual vertical misalignment of ''<IS_TS id=iNameKonstrSciana/>'' type components. The storey with respect to which the alignment correction is to be made must also be indicated. '''ATTENTION!''' This function corrects the position of walls only, corrections in the area of horizontal slab partitions, if required, must be made manually.
<br/>{{#ev:youtube|WTh47McsgNE|900||||rel=0}} <br clear="all"/>
<br/>{{#ev:youtube|WTh47McsgNE|900||||rel=0}} <br clear="all"/>

Revision as of 12:01, 30 December 2021

Product InstalSystem 5
Type of article FUNCTIONS AND TOOLS
Source for translation 2021-11-26


Description

When creating a building structure (e.g. drawing rooms or walls) with the use of raster underlays the AUTO mode cannot be used. As a result of drawing inaccuracies, minute offsets are created between structural elements (e.g. walls) located on successive storeys. These may lead to improper interpretation of the building structure. In order to avoid difficult and time-consuming manual corrections to the structural model, a tool has been made available which automatically corrects the wall geometry. By using the Correction of wall geometry function such artifacts can be eliminated and proper building structure can be obtained.


1. Using the Correction of wall geometry tool.


The Correction of wall geometry tool can be used for the following purposes:

  • Correct wall connections - among other things to rectify wall connections if these were not made correctly with the Automatic walls, slabs and roofs function
  • Correct wall thickness - to standardize wall thicknesses to specified thickness variants
  • Correct angles of the walls - to fix the angles between connected walls
  • Correct position between storeys - to align the positions of walls located one above the other on successive storeys

Examples of use

The Correction of wall geometry tool has four options:

  1. Correct wall connections

  2. Correct wall thickness - enables specifying/removing a permissible wall thickness. The Correct wall thickness tool standardizes the Thickness of a Wall to a defined value across the entire project.

  3. Correct angles of the walls - specifies the value of angle correction of a Wall. The Correct angles of the walls function modifies the value to a grid value, which by default is set to 3. The value is complemented to 90, 93, 96 and so on and adjusted accordingly. The angle shift does not depend on the position of the wall hotpoint.

  4. Correct position between storeys requires specifying the tolerance (in cm) of the mutual vertical misalignment of Wall type components. The storey with respect to which the alignment correction is to be made must also be indicated. ATTENTION! This function corrects the position of walls only, corrections in the area of horizontal slab partitions, if required, must be made manually.