Heating/cooling zone build-up editor: Difference between revisions
No edit summary |
|||
| Line 44: | Line 44: | ||
====''<IS_TS id=strOkladzinaWierzchnia/>''==== | ====''<IS_TS id=strOkladzinaWierzchnia/>''==== | ||
[[File:Floor-build-up-Covering.png|left|thumb|1200px|6. ''<IS_TS id=strOkladzinaWierzchnia/>'']]<br clear="all"/> | [[File:Floor-build-up-Covering.png|left|thumb|1200px|6. ''<IS_TS id=strOkladzinaWierzchnia/>'']]<br clear="all"/> | ||
# ''<IS_TS id=strDomyslnaOkladzina/>'' | # ''<IS_TS id=strDomyslnaOkladzina/>'' originates from ''<IS_TS id=btProjectOptions/>'' for ''<IS_TS id=strs_enumidISFPomieszczenieEN12831_TypUzytkowyPomieszczenia/>'' elements.<br/>[[File:Floor-build-up-Covering-GDM.png|left|thumb|1200px|7. ''<IS_TS id=strDomyslnaOkladzina/>'']]<br clear="all"/> | ||
# ''<IS_TS id=strOkladzinaWierzchnia/>'' | # ''<IS_TS id=strOkladzinaWierzchnia/>'' may be changed for each ''<IS_TS id=strSPGCh/>'' element.<br/>[[File:Floor-build-up-Covering-DEM.png|left|thumb|1200px|8. ''<IS_TS id=strOkladzinaWierzchnia/>'']]<br clear="all"/><br/> | ||
====''<IS_TS id=strGruboscWylewkiCalkowita/>''==== | ====''<IS_TS id=strGruboscWylewkiCalkowita/>''==== | ||
[[File:Floor-build-up-Thickness.png|left|thumb|1200px|9. ''<IS_TS id=strGruboscWylewkiCalkowita/>'']]<br clear="all"/><br/>''<IS_TS id=strGruboscWylewkiCalkowita/>'' w przypadku ustawienia ''<IS_TS id=automanAuto/>'' może się zmieniać adekwatnie do wartości ''<IS_TS id=strMaxDopObciazenie/>'' (''<IS_TS id=_rsssKiloNewtonNaMetrKwadrat/>''), w granicach dopuszczonych przez producenta. Użytkownik może zmienić grubość, również w zakresie dopuszczonym przez producenta systemu, z uwzględnieniem innych danych systemu.<br/>''<IS_TS id=strGruboscWylewkiPonadRura/>'' ''<IS_TS id=strWylewkaSu/>'' jest zawsze przeliczana automatycznie przez program i nie można jej zmieniać ręcznie.<br/><br/> | [[File:Floor-build-up-Thickness.png|left|thumb|1200px|9. ''<IS_TS id=strGruboscWylewkiCalkowita/>'']]<br clear="all"/><br/>''<IS_TS id=strGruboscWylewkiCalkowita/>'' w przypadku ustawienia ''<IS_TS id=automanAuto/>'' może się zmieniać adekwatnie do wartości ''<IS_TS id=strMaxDopObciazenie/>'' (''<IS_TS id=_rsssKiloNewtonNaMetrKwadrat/>''), w granicach dopuszczonych przez producenta. Użytkownik może zmienić grubość, również w zakresie dopuszczonym przez producenta systemu, z uwzględnieniem innych danych systemu.<br/>''<IS_TS id=strGruboscWylewkiPonadRura/>'' ''<IS_TS id=strWylewkaSu/>'' jest zawsze przeliczana automatycznie przez program i nie można jej zmieniać ręcznie.<br/><br/> | ||
Revision as of 14:23, 27 August 2019
Description
This article describes possibilities of editing structural, thermal and operational data of heating/cooling zones and structural partitions, upon which they are located.
Location in the program
Heating/cooling zone build-up editor is situated in: Data table after having ticked: Heating/Cooling Zone and checked the drop-down list Heating floor build-up \ Heating wall build-up \ Construction of heating/cooling ceiling.

Example of use
Presentation of data in the heating/cooling zone build-up editor
- The Heating floor build-up \ Heating wall build-up \ Construction of heating/cooling ceiling field presents overall thickness of the heating/cooling zone as well as overall thermal resistance.
- Having opened the editor, the user gains access to particular data, on the basis of which overall values are calculated:
After data modification in the editor window, it is necessary to recalculate the project to update all values.
Heating/Cooling zone build-up edition
Covering

- Default covering originates from General data for Room type elements.

7. Default covering - Covering may be changed for each Heating/Cooling Zone element.

8. Covering
Overall thickness of the screed/plaster

Overall thickness of the screed/plaster w przypadku ustawienia Auto może się zmieniać adekwatnie do wartości Max. working load (), w granicach dopuszczonych przez producenta. Użytkownik może zmienić grubość, również w zakresie dopuszczonym przez producenta systemu, z uwzględnieniem innych danych systemu.
Thickness of the screed/plaster over the pipe Su jest zawsze przeliczana automatycznie przez program i nie można jej zmieniać ręcznie.
Structural panel

- Użytkownik ma możliwość zmiany płyty systemowej, jeśli:
- Dostępna jest więcej niż jedna dla wybranego systemu mocowania.

11. Structural panel - wybór z General data - W oknie: Data table elementu: Heating/Cooling Zone odznaczył Std. general data - w przeciwnym razie pole to jest wyłącznie w stanie Auto, bez możliwości edycji.

12. Structural panel - wybór z Data table
Insulation option

- Auto
Program dobiera Insulation option o minimalnym oporze wymaganym przez EN 1264: 1:2011 2:2013 3,4:2009 5:2008 dla wybranej płyty systemowej i na podstawie wartości Temperature on other side.
14. Insulation option - Auto - Manual
Można wybrać gotowy Insulation option z katalogu lub zdefiniować własny wybierając poszczególne warstwy izolacji (do wyboru jest maksymalnie 5 warstw).
15. Insulation option - Manual
Structure cross section drawing
Użytkownik może zmienić sposób prezentacji rysunku przekroju płaszczyzny grzewczo-chłodzącej.

Edycja danych konstrukcyjno-cieplnych przegród budowlanych

- Program nie pobiera żadnych danych z elementów: Partition definitions z zakresu obliczeń: Thermal calculations of building i należy je skorygować ręcznie.
- Z okna: General data jest pobierana tylko wartość: Slab thickness.

18. Slab thickness


