==Scope of lesson==
==Scope of lesson==
This article presents the basic path for quick and easy design of underfloor heating installations.
This article presents the basic path for quick and easy design of underfloor heating installations.
Projects, created in '''InstalSmart''' application, can be continued in '''InstalSystem''' application. In turn, opening of projects, created in InstalSystem application, is blocked, and the corresponding message is appeared.
Projects created in '''InstalSmart''' can be further continued in the '''InstalSystem''' application. However, projects created in InstalSystem cannot be opened in InstalSmart.<br/>
 
The '''InstalSmart''' application is limited to only five windows: ''<IS_TS id=rsDanogi/>'', ''<IS_TS id=GraphicalEdit/>'', ''<IS_TS id=ResultModuleTitle/>'', ''<IS_TS id=ErrorModuleTitle/>'' and ''<IS_TS id=DataEditorTable/>'' and has a fixed window layout. The application has one common ribbon with all icons/functions for all editing scopes. '''InstalSmart''' is based on the full '''InstalSystem''' application and allows to prepare simplified projects that can form the basis for initial evaluation of underfloor heating installations.


==Modules and program configuration==  
==Modules and program configuration==  
* '''InstalSmart''' with the modules:
* '''InstalSmart''' is equipped with two primary modules::
**'''Base module'''
**'''Base module'''
**'''<IS_TS id=SystemyPlaszczyznowe/>'''
**'''<IS_TS id=SystemyPlaszczyznowe/>'''
Line 27: Line 29:
==Videos related to the article==
==Videos related to the article==
  <br/>{{#ev:youtube|dOfJG2fXKwE|450||||rel=0}} <br clear="all"/>
  <br/>{{#ev:youtube|dOfJG2fXKwE|450||||rel=0}} <br clear="all"/>
The videos present the topics described in this article, but they aren’t a recording of this lesson.
The video presents the topics described in this article, but they aren’t a recording of this lesson.


==Steps to perform==
==Steps to perform==
Line 35: Line 37:
====Installation, activation, updating====
====Installation, activation, updating====
Install the program via "Install" button.<br/>
Install the program via "Install" button.<br/>
[[File:ISmart Installation.png|900 px|left|thumb|1. InstalSmart5 Manager EN.]]<br clear="all"/>
[[File:ISmart Install.png|900 px|left|thumb|1. InstalSmart5 Manager EN.]]<br clear="all"/>
To activate the free neutral version of the program use the multi-activation license number '''SM-ISFEN-2432-001-YA'''.<br/>[[File:ISmart Activation.png|900 px|left|thumb|2. Program activation.]]<br clear="all"/>
To activate the free neutral version of the program use the multi-activation license number '''SM-ISFEN-2432-001-YA'''.<br/>[[File:ISmart Activation.png|900 px|left|thumb|2. Program activation.]]<br clear="all"/>


Line 44: Line 46:
====Editing the general project data====
====Editing the general project data====
=====<IS_TS id=KTENazwaRodzaju/>=====
=====<IS_TS id=KTENazwaRodzaju/>=====
* Identify the location of the object to obtain the ''<IS_TS id=sENDaneBudynkuTempZewnetrzna/>''.<br/>[[File:ISmart Climatic data.png  |900 px|left|thumb|4.<IS_TS id=KTENazwaRodzaju/>.]]<br clear="all"/>
* Specify the object's location to automatically retrieve ''<IS_TS id=sENDaneBudynkuTempZewnetrzna/>'' based on climatic data.<br/>[[File:ISmart Climatic data.png  |900 px|left|thumb|4.<IS_TS id=KTENazwaRodzaju/>.]]<br clear="all"/>


=====<IS_TS id=StoreyManagement/>=====
=====<IS_TS id=StoreyManagement/>=====
Line 52: Line 54:
=====<IS_TS id=DanePomieszczen/>=====
=====<IS_TS id=DanePomieszczen/>=====
* Choose the ''<IS_TS id=strs_enumidISFOZCDaneOgolneStrataCieplaCalcKindForNewPom/>'' - ''<IS_TS id=rsOZCPomieszczenieStrataCieplaCalcKindWgWskaznika/>'' or ''<IS_TS id=rsOZCPomieszczenieStrataCieplaCalcKindNarzucona/>'';
* Choose the ''<IS_TS id=strs_enumidISFOZCDaneOgolneStrataCieplaCalcKindForNewPom/>'' - ''<IS_TS id=rsOZCPomieszczenieStrataCieplaCalcKindWgWskaznika/>'' or ''<IS_TS id=rsOZCPomieszczenieStrataCieplaCalcKindNarzucona/>'';
* (optionally) Adjust the ''<IS_TS id=strLblWskaznikQPowCaptionHeat/>''.<br/>[[File:ISmart Room data.png|900 px|left|thumb|6.<IS_TS id=DanePomieszczen/>.]]<br clear="all"/>
* (Optionally) Adjust the ''<IS_TS id=strLblWskaznikQPowCaptionHeat/>''.<br/>[[File:ISmart Room data.png|900 px|left|thumb|6.<IS_TS id=DanePomieszczen/>.]]<br clear="all"/>
 
=====<IS_TS id=InstalacjeCieplne/> / <IS_TS id=iNameCOZrodloPlural/>=====
=====<IS_TS id=InstalacjeCieplne/> / <IS_TS id=iNameCOZrodloPlural/>=====
Select the method of determining the supply temperature:
Select the method of determining the supply temperature:
Line 61: Line 64:
* <IS_TS id=DaneInstalacjiPodlogowych/>'':
* <IS_TS id=DaneInstalacjiPodlogowych/>'':
** Specify ''<IS_TS id=ParametryKonstrukcyjne/>'';
** Specify ''<IS_TS id=ParametryKonstrukcyjne/>'';
** Specify ''<IS_TS id=ParametryEksploatacyjne/>''.<br/>[[File:ISmart Floor systems.png|900 px|left|thumb|8.<IS_TS id=InstalacjeCieplne/> / <IS_TS id=SystemyPlaszczyznowe/> / <IS_TS id=DaneInstalacjiPodlogowych/>.]]<br clear="all"/>
** Specify ''<IS_TS id=ParametryEksploatacyjne/>''.<br/>[[File:ISmart Floor systems.png|900 px|left|thumb|8.<IS_TS id=InstalacjeCieplne/> / <IS_TS id=SystemyPlaszczyznowe/> / <IS_TS id=DaneInstalacjiPodlogowych/>.]]<br clear="all"/>'''Note:''' '''InstalSmart''' application does not offer the following options:
'''Note:''' '''InstalSmart''' application does not offer the following options:
** generating loops, so there is no ability to set the ''<IS_TS id=strWariantUlozenia/>'' and to ''<IS_TS id=GenerujRysunkiPetli/>'';
* the option of generating loops, so there is no ability to set the ''<IS_TS id=strWariantUlozenia/>'' and to ''<IS_TS id=GenerujRysunkiPetli/>'';
** inserting the ''<IS_TS id=strStrefaBrzegowa/>'', so the adjustment of ''<IS_TS id=strDostepneOdstepyUkladaniaSB />'' is impossible;
* the option of inserting the ''<IS_TS id=strStrefaBrzegowa/>'', so the adjustment of ''<IS_TS id=strDostepneOdstepyUkladaniaSB />'' is impossible;
** setting the ''<IS_TS id=OdstepPGOdSciany/>'';
* the option to set the ''<IS_TS id=OdstepPGOdSciany/>'';
** pipe-feeds routing, so there is no possibility to specify the settings for the ''<IS_TS id=ProwadzeniePrzylaczy/>'';
* the option pipe-feeds routing, so there is no possibility to specify the settings for the ''<IS_TS id=ProwadzeniePrzylaczy/>'';
** automatically indicating of the ''<IS_TS id=DomThetaDsH/>'' (''<IS_TS id=strTempDSOgrzewanie/>''), so this value can be only ''<IS_TS id=strRbtTiPonizejPodaneCaption/>''.<br/><br/>
* the option of automatically indicating of the ''<IS_TS id=DomThetaDsH/>'' (''<IS_TS id=strTempDSOgrzewanie/>''), so this value can be only ''<IS_TS id=strRbtTiPonizejPodaneCaption/>''.<br/><br/>
* ''<IS_TS id=RozdzielaczeSystemowPlaszczyznowychIAutomatyka/>'':
* ''<IS_TS id=RozdzielaczeSystemowPlaszczyznowychIAutomatyka/>'':
** Specify parameters for the ''<IS_TS id=iNameRozdzielaczPure/>'';
** Specify parameters for the ''<IS_TS id=iNameRozdzielaczPure/>'';
Line 73: Line 75:


====Editing the installation and its data====
====Editing the installation and its data====
=====<IS_TS id=lystrGraphicBackground/> scope=====
* ''<IS_TS id=btImportujPodkladZPlikuDXF/>'';
* Make ''<IS_TS id=strTabSkalowanieCaption/>'' of the ''<IS_TS id=lystrGraphicBackground/>''.<br/>[[File:ISmart Underlay Import Scale.png|900 px|left|thumb|10. <IS_TS id=btImportujPodkladZPlikuDXF/>.]]<br clear="all"/> {{Info}} [[Import underlay files]].<br/>'''Note:''' The usage of IFC format files is not possible in the '''InstalSmart''' application.


====Verifying the correctness of the installation structure====
=====<IS_TS id=lystrFloors/> scope=====
 
* Insert the ''<IS_TS id=rsPomieszczenie/>''. '''InstalSmart''' provides the possibility to insert 2 types of this element:
====Editing installation components data====
*# ''<IS_TS id=rpPomieszczeniePunktowe/>'' - the label of the ''<IS_TS id=rsPomieszczenie/>'' that is placed together with the label of the ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>''. In this case the area of the room needs to be specified manually. The area of the ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' will be automatically determined accordingly.{{#ev:youtube|Lc795UlWVEU|900||||rel=0}}<br/>
*# ''<IS_TS id=rsPomieszczenie/>'' - <IS_TS id=rprsPomieszczenieDesc/>. In this case the area of the room is indicated automatically.<br/>[[File:ISmart Room.png|900 px|left|thumb|11. Inserting <IS_TS id=rsPomieszczenie/>.]]<br clear="all"/> {{Info}} [[Preparation of building structure - Rooms layout#Inserting a room | Inserting a room]].<br/><br/>
* In the ''<IS_TS id=DataEditorTable/>'' specify the ''<IS_TS id=stringSymbol/>'' of the ''<IS_TS id=rsPomieszczenie/>'', ''<IS_TS id=strs_enumidISFPomieszczenieEN12831_TypUzytkowyPomieszczenia/>'' and, where needed,  correct the value of ''<IS_TS id=strTempPomOgrzewanieSymbol/>'' - ''<IS_TS id=TemperaturaPomieszczeniaDlaOkresuGrzania/>''.


===Running the calculations===
=====Radiant - floors and walls scope=====
*If no errors are found during verification, start the calculation of the ''<IS_TS id=InstalacjeKanalizacyjne/>'' by clicking [[File:Tap-Drainage-Calculator.png|25 px]] in the ''<IS_TS id=sObliczenie/>'' section of the toolbar. The calculations finally determine the vertical routing of the pipe-runs.
* Insert ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' for the ''<IS_TS id=rsPomieszczenie/>'' using the ''<IS_TS id=rpSPodlogGChAuto/>'' function;<br/>[[File:ISmart Insert Floor (auto).png|900 px|left|thumb|12. Inserting <IS_TS id=rpSPodlogGChAuto/>.]]<br clear="all"/>
* After the calculations, it is possible to correct manually the vertical passage of pipe-runs in the following way:
* If necessary, correct the parameters of the ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' in the ''<IS_TS id=DataEditorTable/>'':
** imposing proper values in the ''<IS_TS id=DataEditorTable/>'' window for the ''<IS_TS id=iNameSanDzialkaKanalizacjiSanitGraw/>'' element in the following fields: ''<IS_TS id=strSpadekLong/>'', ''<IS_TS id=ZValuePiperunEndPoint1/>'', ''<IS_TS id=ZValuePiperunEndPoint2/>'',
** ''<IS_TS id=strpnPGTypPG/>'': ''<IS_TS id=vltpgStandardowa/>'' or ''<IS_TS id=vltpgOgrzewanaPrzylaczami/>'';
** dividing the chosen pipe-runs into parts and modifying their data. </br> It is recommended to implement such changes gradually and to observe their influence upon the system, as the change in one node after calculations may have a significant impact on positioning of its greater part.
** ''<IS_TS id=strOkladzina/>''.
* '''''Note:''''' Defining the vertical passage of pipe-runs, the program does not exceed the value imposed in the ''<IS_TS id=strMaxSlope/>'' field in the ''<IS_TS id=rsDanogi/>'' window in the ''<IS_TS id=rsDanog_Normy/>'' tab. This value is also automatically propagated to data of all pipe-runs. In case a difference of ordinates between the end of the calculated pipe-run and another pipe-run or a sewage outlet occurs, an additional vertical pipe-run is generated.  To avoid it, allow for a greater gradient, by augmenting individually for each pipe-run a new value in the ''<IS_TS id=strMaxSlopeCaption/>'' field of the ''<IS_TS id=DataEditorTable/>'' and then recalculating the project.
** (Optionally) The checkbox ''<IS_TS id=strpnGrzejStdDaneOgolne/>'' is turned ON by default. <IS_TS id=phintGrzejStdDaneOgolne/>
* (Optionally) Insert ''<IS_TS id=iName2Rozdz/>'' and if necessary to account for correct the data in the ''<IS_TS id=DataEditorTable/>'':
** design length of pipe feeds in the ''<IS_TS id=ZestawienieMaterialowTherm/>'';
** pressure losses in pipe feeds in hydraulic calculations;
** ''<IS_TS id=iNameRozdzielaczPurePlural/>'', ''<IS_TS id=sSzafkiNaRozdzielacze/>'', ''<IS_TS id=strKsztaltki/>'' and ''<IS_TS id=ZestawZaworowRozdz/>'' in the ''<IS_TS id=ZestawienieMaterialowTherm/>'' and hydraulic calculations.<br/>[[File:ISmart insert Manifold.png|900 px|left|thumb|13. Inserting <IS_TS id=iName2Rozdz/>.]]<br clear="all"/>


===Verification of results===
====Calculations and diagnostics====
* After calculations, the system layout should be verified visually by means of the ''<IS_TS id=View3D/>''.
# Launch calculations by clicking the [[File:ISmart Icon Calculations.png|35 px]] icon in the ''<IS_TS id=sObliczenie/>'' section of the toolbar;
* If the calculations end with at least one error, the layout may be unreliable
# Сheck messages the ''<IS_TS id=ErrorModuleTitle/>'' window. First of all, eliminate ''<IS_TS id=cErrorStringPlural/>'';
* The sized diameters of the pipe-runs and fittings can be verified directly in the drawings.<br/>[[File:Visual verification in 3D view.png|900 px|left|thumb|10. Visual verification in the <IS_TS id=View3D/> window.]]<br clear="all"/>
# Verify calculation results in the ''<IS_TS id=ResultModuleTitle/>'' window:
* If a catalogue with visualisation of fittings (like tees, bends etc.) is used in the project, it can helpful in assessing the correctness of fittings selection and sizing for pipe-run nodes (junctions). To do so, node visualisation should be turned on in the ''<IS_TS id=rsDanogi/>'' window, on the ''<IS_TS id=OpcjeRysowania/>'' tab, or using the icon of the ''<IS_TS id=InstallationElementsVisibility/>'' directly in the ''<IS_TS id=View3D/>''.<br/>[[File:Fittings visualisation.png|900 px|left|thumb|11. <IS_TS id=strWizualizacjaKsztaltekKanalizacji/>.]]<br clear="all"/>'''''Note:''''' By default, only the nodes with correctly selected fittings, for which there are no warnings in the ''<IS_TS id=ErrorModuleTitle/>'' window, are visualised. Visualisation of the nodes having angle tolerance warnings may be enabled on request, and they will be drawn in a different colour.<br/>[[File:Incorrectly sized nodes.png|900 px|left|thumb|12. <IS_TS id=ShowFittingsForNodesWithError/>.]]<br clear="all"/>
#* ''<IS_TS id=OPGeneralResultsHeatingTitle/>'';
* Other forms of presentation of calculation results are: component labels and tables of results {{Info}} [[Presentation of the calculations result]] <br/>[[File:Sewage installation Results.png |900 px|left|thumb|13. <IS_TS id=sZestawienieRurKsztaltekIZlaczek/>.]]<br clear="all"/>
#* ''<IS_TS id=DetailedRadiantHeatingResults/>'';
#* ''<IS_TS id=ListaPomieszczenHeatingTitle/>'';
#* ''<IS_TS id=ZestawienieMaterialowTherm/>''.<br/>Every item of the installation presented in the result table can be found in active windows by using [[File:Loupe icon.png|30 px|]] icon.<br/>[[File:ISmart Results tables.png |900 px|left|thumb|14. <IS_TS id=ResultModuleTitle/> window.]]<br clear="all"/>
# If required, adjust the input parameters (e.g. ''<IS_TS id=sTemperaturaZasilania/>'') and recalculate the project to obtain a satisfactory result.<br/><br/>


===Generating schematic views===
====<IS_TS id=GraphicalEdit/> - additional advanced options====
The schematic view will be generated automatically. {{Info}} [[Automatically generate schematic views]].<br/>[[File:Shematic view printout.png |900 px|left|thumb|14. <IS_TS id=SchematicView/>.]]<br clear="all"/>
=====<IS_TS id=lystrFloors/> scope=====
A ''<IS_TS id=Label/>'' with list of fittings may be added manually to each ''<IS_TS id=PiperunEndNode/>''. <br/>[[File:Label junctions.png |900 px|left|thumb|15. Add the <IS_TS id=Label/> to each <IS_TS id=PiperunEndNode/> manually.]]<br clear="all"/> '''''Note:''''' After obtaining the schematic view, fittings may be added on any pipe-run on the schematic view worksheet, that may be the best solution for vertical pipe-runs.
* '''InstalSmart''' allows to convert ''<IS_TS id=rpPomieszczeniePunktowe/>'' into ''<IS_TS id=rsPomieszczenie/>'' by simple imposition. In this case the program will automatically determine the area of the ''<IS_TS id=rsPomieszczenie/>'' and insert the ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' in accordance with the data of the ''<IS_TS id=rpPomieszczeniePunktowe/>''. The same operation can be done in '''InstalSystem''' application.<br/>'''Attention:''' If the area of the ''<IS_TS id=rsPomieszczenie/>'' is to be set according to the drawing, switch the ''<IS_TS id=strs_expidISFPomieszczeniePowierzchniaWSwietle/>'' (''<IS_TS id=strl_expidISFPomieszczeniePowierzchniaWSwietle/>'') field to the automatic mode.{{#ev:youtube|mPMlnjV9krs|900||||rel=0}}<br/>
* In the case of necessity to improve the shape of the ''<IS_TS id=rsPomieszczenie/>'', use ''<IS_TS id=InsertEndPoint/>'' function from the right mouse button context menu.<br/>[[File:ISmart Insert dividing point.png|900 px|left|thumb|15. <IS_TS id=InsertEndPoint/>.]]<br clear="all"/>


===Preparing drawings for export/printing===
=====Radiant - floors and walls scope=====
# To have the results for pipe-runs and installation nodes included in the printout of a drawing, appropriate labels must be inserted {{Info}} [[Export / print results and drawings#Preparation of drawings for export / printing|Preparation of drawings for export / printing]]
'''InstalSmart''' provides the opportunity to divide ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' into a defined number of parts or along a drawn line without or with ''<IS_TS id=DylatacjaCaption/>'' using the functions from the  the right mouse button context menu.<br/>[[File:ISmart Divide zone.png |900 px|left|thumb|16. <IS_TS id=PodzielStrefe/>.]]<br clear="all"/>
# Completed drawings can be printed and/or exported  {{Info}} [[Export / print results and drawings]]


===BIM - Export of the installation to an IFC model===
====Printing of the results tables====
Specify the required settings and execute export of the installation using the ''<IS_TS id=rpExportPlikuIFC/>'' icon  on the ''<IS_TS id=NarzedziaGlowne/>'' bar in the ''<IS_TS id=strWydrukIEksport/>'' section when the ''<IS_TS id=lystrPrintPreview/>'' editing scope is active.<br/>[[File:BIM - Export.png |900 px|left|thumb|16. <IS_TS id=rpExportPlikuIFC/>.]]<br clear="all"/>
Print or save at any convenient format the tables with calculation ''<IS_TS id=ResultModuleTitle/>''.<br/>'''Note:''' '''InstalSmart''' doesn't allow to print and export the drawings.<br/>[[File:ISmart Results.png |900 px|left|thumb|17. Printing or saving <IS_TS id=ResultModuleTitle/>.]]<br clear="all"/>
{{Info}} [[BIM - Export of installation and construction data from the project to IFC models]].


====Saving the project and continuing it in the InstalSystem application====
Proceed to save the project and, if necessary, continue working on it in '''InstalSystem''' application in accordance with [[Designing of radiant heating installation on the basis of data from the Smart application]].
[[Category:InstalSmart]]
[[Category:InstalSmart]]
[[Category:DESIGNING LESSON]]
[[Category:DESIGNING LESSON]]

Latest revision as of 14:45, 3 October 2024

Product InstalSmart
Type of article DESIGNING LESSON
Source for translation 2024-09-09


Scope of lesson

This article presents the basic path for quick and easy design of underfloor heating installations. Projects created in InstalSmart can be further continued in the InstalSystem application. However, projects created in InstalSystem cannot be opened in InstalSmart.

The InstalSmart application is limited to only five windows: General data, 2D editor, Results, Diagnostics and Data table and has a fixed window layout. The application has one common ribbon with all icons/functions for all editing scopes. InstalSmart is based on the full InstalSystem application and allows to prepare simplified projects that can form the basis for initial evaluation of underfloor heating installations.

Modules and program configuration

  • InstalSmart is equipped with two primary modules::
    • Base module
    • Radiant systems

Videos related to the article



The video presents the topics described in this article, but they aren’t a recording of this lesson.

Steps to perform

Preparing the working environment

Gaining access to the application

Download the program installation file from our website: Installation files.

Installation, activation, updating

Install the program via "Install" button.

1. InstalSmart5 Manager EN.


To activate the free neutral version of the program use the multi-activation license number SM-ISFEN-2432-001-YA.

2. Program activation.


Creating the project file

Create the project using the New project function.

3. New project creation.


Working with the project

Editing the general project data

Climatic data
  • Specify the object's location to automatically retrieve External temperature, design based on climatic data.
    4.Climatic data.

Storeys management
  • Create the required number of storeys;
  • Specify Symbol and Description for each Storey;
  • Fill in the sections Position and Sizes.
    5.Storeys management.

Room data
  • Choose the Method of calculating Φ - Calculated acc. to coefficient or User specified;
  • (Optionally) Adjust the Heat loss index Φsurf,H.
    6.Room data.

Thermal systems / Sources

Select the method of determining the supply temperature:

  • Optimized by the program in accordance with min. investment costs or heat output and press. drop;
  • Impose supply temperature manually.
    7.Thermal systems / Sources.

Thermal systems / Radiant systems
  • Floor systems:
    • Specify Structural parameters;
    • Specify Operating parameters.
      8.Thermal systems / Radiant systems / Floor systems.

      Note: InstalSmart application does not offer the following options:
    • generating loops, so there is no ability to set the Pipe laying pattern and to Generate loops drawings;
    • inserting the Peripheral zone (PZ), so the adjustment of Available spacing in PZ is impossible;
    • setting the H/C Area spacing from wall;
    • pipe-feeds routing, so there is no possibility to specify the settings for the Pipe feeds arrangement;
    • automatically indicating of the Default value θos,H (Temperature on the opposite side during heating period), so this value can be only User specified.

  • Manifolds, fittings and control:
    • Specify parameters for the Manifold;
    • Specify parameters for the Circuit control system.
      9.Thermal systems / Radiant systems / Manifolds, fittings and control.

Editing the installation and its data

Underlay scope
  • Import underlay;
  • Make Scaling of the Underlay.
    10. Import underlay.

    For more information, see: Import underlay files.
    Note: The usage of IFC format files is not possible in the InstalSmart application.
Construction scope
  • Insert the Room. InstalSmart provides the possibility to insert 2 types of this element:
    1. Point room - the label of the Room that is placed together with the label of the Heating/Cooling Floor Zone. In this case the area of the room needs to be specified manually. The area of the Heating/Cooling Floor Zone will be automatically determined accordingly.

    2. Room - Allows to create contours of rooms. In this case the area of the room is indicated automatically.
      11. Inserting Room.

      For more information, see: Inserting a room.

  • In the Data table specify the Symbol of the Room, Room type and, where needed, correct the value of θi,H - Design room temperature.
Radiant - floors and walls scope
  • Insert Heating/Cooling Floor Zone for the Room using the Floor (auto) function;
    12. Inserting Floor (auto).

  • If necessary, correct the parameters of the Heating/Cooling Floor Zone in the Data table:
    • H/C Zone type: Standard or Heated/cooled by pipe feeds;
    • Covering.
    • (Optionally) The checkbox Std. general data is turned ON by default. Checkbox ON - program will apply default settings from "General data" window.
      Checkbox OFF - program will allow to set parameters individually.
  • (Optionally) Insert Double apartment manifold and if necessary to account for correct the data in the Data table:
    • design length of pipe feeds in the Bill of materials - heating / cooling;
    • pressure losses in pipe feeds in hydraulic calculations;
    • Manifolds, Manifold cabinets, Pipe fittings and Manifold valves set in the Bill of materials - heating / cooling and hydraulic calculations.
      13. Inserting Double apartment manifold.

Calculations and diagnostics

  1. Launch calculations by clicking the icon in the Calculations section of the toolbar;
  2. Сheck messages the Diagnostics window. First of all, eliminate Errors;
  3. Verify calculation results in the Results window:
    • Radiant heating general results;
    • Detailed radiant heating results;
    • List of rooms - heating;
    • Bill of materials - heating / cooling.
      Every item of the installation presented in the result table can be found in active windows by using icon.
      14. Results window.

  4. If required, adjust the input parameters (e.g. Supply temperature) and recalculate the project to obtain a satisfactory result.

2D editor - additional advanced options

Construction scope
  • InstalSmart allows to convert Point room into Room by simple imposition. In this case the program will automatically determine the area of the Room and insert the Heating/Cooling Floor Zone in accordance with the data of the Point room. The same operation can be done in InstalSystem application.
    Attention: If the area of the Room is to be set according to the drawing, switch the Af (Room area within partition faces|Room area faces) field to the automatic mode.

  • In the case of necessity to improve the shape of the Room, use Insert dividing point function from the right mouse button context menu.
    15. Insert dividing point.

Radiant - floors and walls scope

InstalSmart provides the opportunity to divide Heating/Cooling Floor Zone into a defined number of parts or along a drawn line without or with Expansion joint using the functions from the the right mouse button context menu.

16. Divide zone ....


Printing of the results tables

Print or save at any convenient format the tables with calculation Results.
Note: InstalSmart doesn't allow to print and export the drawings.

17. Printing or saving Results.


Saving the project and continuing it in the InstalSystem application