How to eliminate: "Cannot apply any pipe spacing": Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary Tag: Manual revert |
||
| (3 intermediate revisions by 2 users not shown) | |||
| Line 34: | Line 34: | ||
# Too limited number of available pipe spacing options. | # Too limited number of available pipe spacing options. | ||
#* Turning on of additional pipe spacing options on the ''<IS_TS id=strDostepneOdstepyUkladania/>'' list.<br/>[[File:TP-Cannot-apply-any-pipe-spacing-VA.png|900 px|thumb|left|1. ''<IS_TS id=strDostepneOdstepyUkladania/>'']]<br clear="all"/> | #* Turning on of additional pipe spacing options on the ''<IS_TS id=strDostepneOdstepyUkladania/>'' list.<br/>[[File:TP-Cannot-apply-any-pipe-spacing-VA.png|900 px|thumb|left|1. ''<IS_TS id=strDostepneOdstepyUkladania/>'']]<br clear="all"/> | ||
{|class="wikitable" style="width: 800px; margin: 0 auto;" | |||
!If you have any comments on this article, please send us a short message at ''info@instalsoft.com'' | |||
|} | |||
[[Category:InstalSystem 5]] | [[Category:InstalSystem 5]] | ||
| Line 39: | Line 45: | ||
<!-- Do not write text below this tag --> | <!-- Do not write text below this tag --> | ||
<br class="iwlinks"/>[[pl:Jak wyeliminować: "Nie można dobrać żadnego odstępu układania"|Jak wyeliminować: "Nie można dobrać żadnego odstępu układania | <br class="iwlinks"/>[[pl:Jak wyeliminować: "Nie można dobrać żadnego odstępu układania"|Jak wyeliminować: "Nie można dobrać żadnego odstępu układania"]][[fa:از بین بردن ایراد : "نمی توان هیچ فاصله لوله ای اعمال کرد."|از بین بردن ایراد : "نمی توان هیچ فاصله لوله ای اعمال کرد."]][[zh-cn:如何删除: "不能选用任何的管间距"|如何删除: "不能选用任何的管间距"]][[bg:Как да елиминирате: "Не може да приложи стъпка на тръба"|Как да елиминирате: "Не може да приложи стъпка на тръба"]] | ||
Latest revision as of 23:03, 12 June 2026
| Product | InstalSystem 5 |
| Type of article | TIP&TRICK |
| Source for translation | 2020-04-05 |
Description
The message is displayed when the program cannot select pipe spacing among available options:
- CANNOT APPLY ANY PIPE SPACING
Lack of possibility to choose pipe spacing is usually caused by:
- too high radiant system supply temperature,
- limited number of available pipe spacing options.
Solution
- Too high radiant system supply temperature.
- Insertion of covering to Heating/Cooling Zone.
- Corection (lowering) of radiant system supply temperature.
- Correction (rise) θsurf max - maximum heating/cooling surface temperature.
- Insertion of covering to Heating/Cooling Zone.
- Too limited number of available pipe spacing options.
| If you have any comments on this article, please send us a short message at info@instalsoft.com |
|---|