How to eliminate problems with radiant system loops: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
(Odpowiedz TP na Case 165515)
 
No edit summary
 
(9 intermediate revisions by 4 users not shown)
Line 1: Line 1:
The article has been to: [[Appending drawings with radiant system loops]].
<!--
{{Article table
{{Article table
|commercial_product1=InstalSystem 5
|commercial_product1=InstalSystem 5
|p2                =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy2="-->
 
|p3                =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy3="-->
|category1          =InstalSystem 5#Tips&Tricks
|p4                =<!--gdy jest kolejny produkt handlowy, zamienić na->"produkt_handlowy3="-->
|category_name1    =TIP&TRICK
|category1          =InstalSystem 5#Typical problems
 
|category_name1    =TYPICAL PROBLEM
|version1          =2016-07-26
|c2                =<!--Jest kategoria -> zamienić na: "category2=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
 
|category_name2    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|c3                =<!--Jest kategoria -> zamienić na: "category3=" i uzupełnić link do sekcji kategorii na stronie głównej produktu-->
|category_name3    =<!--podać nazwę kategorii "ZASTOSOWANIE"/"FUNKCJONALNOŚĆ"/...-->
|version1          =[[Release notes InstalSystem 5#Version BETA 31 Rev. 0.0.B31|IS 5.0 Beta 31]]
|v2                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
|v3                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
|v4                =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu-->
}}
}}
==Problem description==
==Problem description==
Problems associated with automatic generation of pipe feeds using the ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' tool are diagnosed by means of the following message:
Problems associated with automatic generation of loops drawings.
* '''''<IS_TS id=strErrNieUdaloSieUlozycPrzylaczy/>'''''.
The message informs that pipe feeds could not be generated automatically by means of the ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' tool, due to the following reasons:
* specified or automatically sized arrangement spacings are too large,
* manner of component crossing ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' is inappropriate (for the algorithm of automatic pipe feed arrangement),
* number of component crossings ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' is too large,
* ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' components are located too close to each other,
* width of the strip within which ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' generates pipe feeds is too small or too large (reaches beyond the borders of the heating zone).


==Solution==
==Solution==
* Specify smaller pipe feed arrangement spacing.
* Change pipe feed arrangement spacing.