Designing of radiant heating installation on the basis of data from the Smart application

From HelpSystem
Jump to: navigation, search
Product InstalSystem 5
Type of article DESIGN APPLICATION
Source for translation IS 5.0 Beta 31


Scope of lesson

The article presents the manner of designing a radiant heating system when the starting point is a project file generated by means of the InstalSystem SMART mobile application.

Modules and program configuration

InstalSystem 5 with the module:

  • Radiant systems

Inital state

The project contains:

  • catalogues and default data,
  • building structure (storeys, rooms represented by labels) including storey plan drawing,
  • manifolds.

More details: Table of a project example.

Steps to perform

SAMPLE PROJECT IN INSTALSYSTEM
Project files

How to calculate downloaded file?

Initial state
Designed with InstalSystem 5 Rev. Beta 31
Required modules InstalSystem basis
Heating system 5
Radiant loop systems 5
Project range Radiant heating
Used catalogues

Basic radiant systems
Brass, cast iron and steel fittings
Copper pipes and fittings EN 1057
Miscellaneous fittings any manufacturer
Standard insulation catalogue
Neutral valves catalogue - typical construction

Type of building hotel
no basement
2-storey
Building structure
Drawings range Plan drawing
Prepared by Logo-instalsoft-new.png
www.instalsoft.com
Legal disclaimer Copy all or fragments allowed
Calculation results
Drawing results


Opening the project file

  1. Open the project file created with the InstalSystem SMART mobile application.
    For more information, see: Project and application management and InstalSystem Smart 5 - Quick sizing and estimation of underfloor heating system

Preparing the building structure

  1. Rescale the base drawings used in the mobile application preserving the arrangement of inserted components.
    For more information, see: Import files
  2. Check the locations of room labels - these should be located inside the rooms shown in the base drawing.
  3. Redraw the rooms in the rescaled base drawing.
    For more information, see: Preparation of building structure
    Data of rooms created with the mobile application will be adopted if the room label is within the room created with InstalSystem 5.

  4. Check the data in the Data table of the Room. Some default data are not transferred automatically to component data.
    For more information, see: Preparation of building structure

Editing the system - radiant system

Heating/Cooling Zone

  1. Adjust the shape of Heating/Cooling Zone.

Manifold

  1. Adjust manifold arrangement.

Editing system component data

Check the data in the Data table. Some default data are not transferred automatically to component data.

Continue working on the project in accordance with: Design of radiant heating floor and wall installation.